background image

EULA

VI

   BC9600/BC9620 BASE STATIONS

End User specifically agrees not to export or re-export any of the Software: (i) to any country

to  which  the  U.S.  has  embargoed  or  restricted  the  export  of  goods  or  services  or  to  any

national of any such country, wherever located, who intends to transmit or transport the Soft

-

ware  back to such country; (ii) to any person or entity who you know or have reason to know

will utilize the Software  in the design, development or production of nuclear, chemical or bio

-

logical weapons; or (iii) to any person or entity who has been prohibited from participating in

U.S. export transactions by any federal agency of the U.S. government. End User warrants and

represents that neither the U.S. Commerce Department, Bureau of Export Administration nor

any other U.S. federal agency has suspended, revoked or denied its export privileges.

9. Third Party Software

The Datalogic Product may contain one or more items of third party software which use is governed

by separate third party license, unless otherwise stated.

10. Open Source Software

Portions of the Software include or operate with Open Source software (“Open Source Software”). 

Open  Source  Software  is  software  covered  by  a  publicly  available  license  governed  solely  under

Copyright  law,  whereas  the  complete  terms  and  obligations  of  such  license  attach  to  a  licensee

solely through the act of copying, using and/or distributing the licensed software, such obligations

often include one or more of attribution obligations, distribution obligations, copyleft obligations,

and  intellectual  property  encumbrances.  The  use  of  any  Open  Source  Software  is  subject  to  the

terms and conditions of this Agreement as well as the terms and conditions of the corresponding

license of each Open Source Software package. If there is a conflict between the terms and condi

-

tions  of  this  Agreement  and  the  terms  and  conditions  of  the  Open  Source  Software  license,  the

applicable Open Source Software license will take precedence. Datalogic is required to reproduce

the software licenses, acknowledgments and copyright notices as provided by the authors and own

-

ers, thus, all such information is provided in its native language form, without modification or trans

-

lation. Please reference and review the above mentioned information to identify which Open Source

Software packages have source code provided or available.

11. Notices

All notices required or authorized under this Agreement shall be given in writing, and shall be effec

-

tive when received, with evidence of receipt. Notices to Datalogic shall be sent to the attention of

Datalogic IP Tech 

S.r.l., Legal & IP Department, Via San Vitalino 13, 40012 Calderara di Reno (Bolo

-

gna), Italy, or such other address as may be specified by Datalogic in writing.

12. General Provisions.

12.1. Entire Agreement; Amendment. This document contains the entire agreement between the

parties relating to use of the Datalogic Products and the licensing of the Software and super

-

sedes all prior or contemporaneous agreements, written or oral, between the parties concern

-

ing the use of the Datalogic Products and licensing of the Software. This Agreement may not

be changed, amended, or modified except by written document signed by Datalogic.

12.2. Waiver. A party's failure to enforce any of the terms and conditions of this Agreement shall not

prevent the party's later enforcement of such terms and conditions.

12.3. Governing Law; Venue: End User agrees to the application of the laws of the country in which

End User obtained the license to govern, interpret, and enforce all of End User’s and Data

-

logic’s respective rights, duties, and obligations arising from, or relating in any manner to, the

subject  matter  of  this  Agreement,  without  regard  to  conflict  of  law  principles.  The  United

Nations Convention on Contracts for the International Sale of Goods does not apply.
All rights, duties, and obligations are subject to the courts of the country in which End User

obtained the license. For licenses granted by Licensee who operates in the countries specified

below, the following terms applies. 

For Americas:

This Agreement is governed by the laws of the State of Oregon. This Agreement and the rights of the

parties hereunder shall be governed by and construed in accordance with the laws of the State of

Oregon U.S.A, without regard to the rules governing conflicts of law. The state or federal courts of

the State of Oregon located in either Multnomah or Lane counties shall have exclusive jurisdiction

over all matters regarding this Agreement, except that Datalogic shall have the right, at its absolute

discretion, to initiate proceedings in the courts of any other state, country, or territory in which End

User resides, or in which any of End User's assets are located. In the event an action is brought to

Summary of Contents for PowerScan BC9620

Page 1: ...PowerScan BC9600 BC9620 Base Stations QUICK REFERENCE GUIDE Industrial Base Station Charger for PowerScan 9600 Family Bar Code Readers...

Page 2: ...t may be downloaded from the Datalogic website www data logic com If you visit our website and would like to make comments or suggestions about this or other Datalogic publications please let us know...

Page 3: ...for BC9620 models 8 System Connections 11 BC9681 Power Over Ethernet PoE Connection 15 BC9681 External Power Connection 15 BC9680 BC9681 Power Over Ethernet PoE Connection 16 Connecting and Disconnec...

Page 4: ...other party without Datalogic s prior written consent 1 3 Title to the licensed Software shall be and remain with Datalogic or the third party from whom Datalogic has obtained a license right This Ag...

Page 5: ...ENCE PRODUCT LIABILITY STRICT LIABILITY WARRANTY OR ANY OTHER BASIS EXCEED THE PRICE OR FEE PAID BY END USER FOR THE DATALOGIC PRODUCT UNDER NO CIRCUMSTANCES SHALL DATALOGIC OR ITS LICENSORS BE LIABLE...

Page 6: ...y which Open Source Software packages have source code provided or available 11 Notices All notices required or authorized under this Agreement shall be given in writing and shall be effec tive when r...

Page 7: ...s for the time being in force which rules are deemed to be incorporated by reference in this clause The seat of the arbitration shall be Singapore The number of arbitrators will be three with each sid...

Page 8: ...EULA VIII BC9600 BC9620 BASE STATIONS NOTES...

Page 9: ...tery profile different from Max Autonomy that are linked to that base station and within the radio range coverage will emit a beep and blink within 5 seconds This feature is useful to verify which sca...

Page 10: ...NET BC9680 910 BASE CHARGER 910MHZ ETH PROFINET BC9681 433 N100 BASE CHARGER 433 ETH PROFINET IP65 BC9681 433 N200 BASE CHARGER 433 ETH ETH IP IP65 BC9681 910 N100 BASE CHARGER 910 ETH PROFINET IP65 B...

Page 11: ...t up your BC9600 base station you must 1 Physically install it 2 Make all system connections 3 Configure it PACKAGE CONTENTS The base station package contains the following items BC9600 Base Station w...

Page 12: ...T MOUNTING For either desktop or wall mounting the base station can be fastened directly to a flat surface using screws not included NOTE When the base station is mounted on vertical surfaces perma ne...

Page 13: ...en shipped the base station has the positioning tab installed in the Desktop position horizontal For vertical installation the positioning tab must be rotated Changing the Orientation of the Positioni...

Page 14: ...base station fast release by first fixing the mounting plate onto a flat surface so the base station can be slid off and on or 2 connection module fast release by fixing the mounting plate to the con...

Page 15: ...ICK REFERENCE GUIDE 7 2 Remove the adhesive strips protecting the mounting tabs on the base sta tion 3 Align the base station with the mounting plate until you see the sphere inside the bigger hole on...

Page 16: ...n down until the sphere is aligned with the smaller hole Connection Module Fast Release Mounting the Bracket not valid for BC9620 models 1 Remove the protective strips 2 Unscrew the connection module...

Page 17: ...se sta tion 5 Screw the connection module and mounting plate sub assembly to a flat surface using four screws as shown in the figure below 6 With the lever still unlocked align the base station with t...

Page 18: ...Portable Desktop Mounting 10 BC9600 BC9620 BASE STATIONS 7 Move the base station up until the sphere is aligned with the smaller hole then lock the lever to secure the connection module Lock the lever...

Page 19: ...ock the USB cable of BC9620 push the button shown in the picture and extract the cable To unlock the multi interface cable of BC9630 first lift the lever and then extract the cable as indicated by the...

Page 20: ...NS The BC9631 BC9600 CM9631 connection module provides a single multi interface connector Power is supplied by the host USB or by an external power supply connected to the cable Figure 4 BC9631 connec...

Page 21: ...is case the full charging of an empty battery will take about 16 hours with an approved USB cable type A and 6 5 hours with an approved USB cable type C at ambient temperature For intense usage and or...

Page 22: ...TE When using the BC9680 BC9681 cradles apply the ferrite pro vided with the device to the Ethernet cable 5 cm from the cradle See the example below BC9620 BC9631 BC9680 BC9681 POE connection BC9681 E...

Page 23: ...any of the data pairs according to the IEE 802 3af standard for Alternative A Mid and Endspan or Alternative B BC9681 External Power Connection PIN NAME DESCRIPTION 1 TX Transmit Data 2 TX Transmit D...

Page 24: ...5A251300 3 POLE STRAIGHT CABLE 7M 95A251320 3 POLE STRAIGHT CABLE 10M 95A251340 CAB ETH X RJ ADAPTER FULL GETH X to RJ45 93A050141 CAB ETH X M01 M12 IP67 GETH X CAB 1M 93A050122 CAB ETH X M03 M12 IP67...

Page 25: ...able first then connect the power adapter cable Finally power on the base station After connecting the power supply cable secure it on the strain relief as shown in the figure below Disconnecting BC96...

Page 26: ...System Connections 18 BC9600 BC9620 BASE STATIONS Pull out the multi interface cable and put the lever back into lock position Unlock the lever Press down the cable clip Cable clip Lock position...

Page 27: ...nnect the cable first then connect the power adapter cable The cable should click when fully inserted Finally power on the base station Disconnecting BC9620 cables To disconnect the cables power off t...

Page 28: ...multi interface cable Unscrew the no tool screw to open the front door connect the multi inter face cable close the door and screw it back To disconnect the multi interface cable open the front door p...

Page 29: ...e power adapter cable Finally power on the cradle and lock the power cable on the strain relief To disconnect the cables first unlock the power cable and then pull it out To disconnect the Ethernet ca...

Page 30: ...vides a quick and user friendly con figuration method via the RS232 USB COM or Ethernet interface It also allows upgrading the software of the connected device see the Datalogic Aladdin Help On Line f...

Page 31: ...E Injector IEEE 802 3af or superior compliant a with approved interface cables Power Consumption max 1 5 A charging max 500 mA 5 V charging Indicators Power Data green LED Reader battery state green o...

Page 32: ...excellent source for technical assistance and information is an authorized Datalogic reseller A reseller is acquainted with specific types of businesses application software and computer systems and...

Page 33: ...hole unit consumable items 7 use of counterfeit or replacement parts that are neither man ufactured nor approved by Datalogic for use in Datalogic manufactured Products 8 any damage or malfunctioning...

Page 34: ...Warranty 26 BC9600 BC9620 BASE STATIONS...

Page 35: ......

Page 36: ......

Page 37: ......

Page 38: ...mitted in any form or by any means or for any purpose without the express written permission of Datalogic S p A and or its affiliates Datalogic and the Datalogic logo are registered trademarks of Dat...

Reviews: