RS-232 Parameters
Product Reference Guide
285
Enable Character
Specifies the value of the RS-232 host command used to enable the reader.
ASCII characters or any hex value from 0 to 0xFF can be selected.
Setting to previously defined characters such as XON, XOFF,
or host commands conflicts with normal operation of these
characters.
To set this feature:
Determine the desired character or value.
A setting of 0xFF indicates the
Enable Character is not used (not available).
1. Determine the desired character or value.
2. Use the
on the inside back cover of this manual to find the
hex equivalent for the desired character/value.
3. Go to
and scan the ENTER/EXIT PROGRAMMING MODE bar code
to enter Programming Mode.
4. Scan the bar code: SELECT ENABLE CHARACTER SETTING.
5. Scan the appropriate two alphanumeric characters from the keypad in
, that represent the desired character/value in step
2 above. The second character will cause a two-beep indication.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Program-
ming Mode.
This completes the procedure. See
for some examples of how to
set this feature.
Table 34. Enable Character Setting Examples
STEP
ACTION
EXAMPLES
1
Desired character/value
‘e’
‘}’
‘E’
Enable Command
Not Used
2
Hex equivalent from
0x65
0x7D
0x45
0xFF
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT ENABLE CHARACTER VALUE SETTING
5
Scan Two Characters
From
‘6’ and ‘5’
‘7’ and ‘D’
‘4’ and ‘5’
‘F’ AND ‘F’
6
Scan ENTER/EXIT PROGRAMMING MODE
Summary of Contents for PowerScan 9501-AR Series
Page 32: ...Setup 22 PowerScan PD9531 AR PBT9501 AR PM9501 AR NOTES...
Page 36: ...Configuration Using Bar Codes 26 PowerScan PD9531 AR PBT9501 AR PM9501 AR NOTES...
Page 92: ...Enter Exit Programming Mode 82 PowerScan PD9531 AR PBT9501 AR PM9501 AR NOTES...
Page 184: ...174 PowerScan PD9531 AR PBT9501 AR PM9501 AR NOTES...
Page 318: ...References 308 PowerScan PD9531 AR PBT9501 AR PM9501 AR NOTES...
Page 322: ...Message Formatting 312 PowerScan PD9531 AR PBT9501 AR PM9501 AR NOTES...
Page 360: ...Scancode Tables 350 PowerScan PD9531 AR PBT9501 AR PM9501 AR...