Enter/Exit Programming Mode
Product Reference Guide
109
Code 39 Quiet Zones
This feature specifies the number of quiet zones for Code 39 labels. Quiet
zones are blank areas at the ends of a bar code, typically 10 times the width
of the narrowest bar or space in the label.
Code 39 Quiet Zones = Quiet Zones on two sides
Code 39 Quiet Zones = Small Quiet Zones on two sides
DEFAULT
Code 39 Length Control
This feature specifies either variable length decoding or fixed length decod-
ing for the Code 39 symbology.
Variable Length:
For variable length decoding, a minimum and maximum
length may be set.
Fixed Length:
For fixed length decoding, two different lengths may be set.
DEFAULT
Code 39 Length Control = Variable Length
Code 39 Length Control = Fixed Length
Summary of Contents for PowerScan 9501-AR Series
Page 32: ...Setup 22 PowerScan PD9531 AR PBT9501 AR PM9501 AR NOTES...
Page 36: ...Configuration Using Bar Codes 26 PowerScan PD9531 AR PBT9501 AR PM9501 AR NOTES...
Page 92: ...Enter Exit Programming Mode 82 PowerScan PD9531 AR PBT9501 AR PM9501 AR NOTES...
Page 184: ...174 PowerScan PD9531 AR PBT9501 AR PM9501 AR NOTES...
Page 318: ...References 308 PowerScan PD9531 AR PBT9501 AR PM9501 AR NOTES...
Page 322: ...Message Formatting 312 PowerScan PD9531 AR PBT9501 AR PM9501 AR NOTES...
Page 360: ...Scancode Tables 350 PowerScan PD9531 AR PBT9501 AR PM9501 AR...