Resetting the Pegaso
24
Pegaso™ Industrial PDA with Windows
®
CE
Cold Reset
A cold reset is a complete reset of the Pegaso in which all applications are forc-
ibly closed and working RAM is cleared.
Reason to Cold Reset —
Press the
<Reset>
button inside the Battery com-
partment when the Windows CE operating system locks up and the warm reset
command does not work.
Procedure to Cold Reset —
To perform a cold reset, remove the Battery
Pack and use the Stylus to press the
<Reset>
button inside the Battery Compart-
ment, shown in
. Reinstall the Battery Pack, and press the
<Power>
button.
Figure 15. Cold Reset
After Cold Reset
Cold reset clears the working RAM and initializes the file system. You will lose
any applications and data which are not stored in persistent flash memory (refer
to the PRG for more information).
• The splash screen will appear after a short period.
• Recalibrate the touch screen.
• The desktop appears with the application shortcuts on the screen.
CAUTION
Datalogic recommends that you always attempt a warm reset before
initiating a cold reset. Once you initiate a cold reset, all applications
are forcibly closed and working RAM and files are cleared.
Any applications, files, or data in RAM will be lost on cold reset. Only
applications and files in persistent memory are preserved. Refer to
Persistent Memory on page 22 for information on preserving appli-
cations and files with persistent flash storage memory.
Cold Reset Button