2-28
Magellan
®
8300/8400
3. Rotate the Interior Lift Handle up as shown in
Figure 2-23
and
hook the fingers of both hands in the lift handles indicated. DO
NOT attempt to lift the unit using the plastic edges, scale frame, or
any features other than the lift handles.
4. Lower the unit into the counter opening, ensuring that none of the
cables are pinched, pierced or crimped.
5. Re-install the Platter and verify that it is flush or just below flush
with the countertop. This is necessary to provide smooth scanning
from either direction. Make adjustments as needed to align the plat-
ter with the counter by moving support rails up or down, or con-
sider installing screws in positions that will allow their use in
adjusting the unit’s position.
6. Once installation is complete, proceed with the
Scale Diagnostic
Mode
procedures that follow.
Figure 2-23. Using the Lift Handles
NOTE
Failure to install a scanner/scale in a stable and level position will inhibit
weighing, calibration and zeroing operations. The platter MUST make unob-
structed contact with all of its supports for proper weighing operation.
Rear Lift
Handle
Interior Lift Handle
Summary of Contents for MAGELLAN 8300
Page 1: ...MagellanTM 8300 8400 Technical Guide...
Page 3: ...Product Reference Guide 3...
Page 4: ......
Page 16: ...1 10 Magellan 8300 8400 NOTES...
Page 64: ...4 12 Magellan 8300 8400 NOTES...
Page 83: ...Interface Related Features Technical Guide 5 19 NOTES...
Page 84: ...5 20 Magellan 8300 8400 NOTES...