background image

6

Magellan™ 3400VSi

Camera Button

The Camera Button provides the unit with the ability to capture 
images. See 

Camera Button Mode on page 12

 to enable this fea-

ture. Destination and image type can be specified. Reference the 
PRG for additional information and programming options.

LED and Beeper Indicators

The scanner’s beeper sounds and its green LED illuminates to 
indicate various functions or errors on the scanner. The tables 
that follow list these indications. An exception is that the scan-
ner’s functions are programmable, and may or may not be turned 
on. For example, some indications (such as the power-up beep) 
can be disabled using programming bar code labels.

LED 

INDICATION

INDICATION

COMMENT

Power-on 
indication

Bright green flash

Indicates the scanner has finished all its 
power-up tests and is now ready for 
operation.

Good Read
Indication

Bright green flash

Indicates a bar code has been read and 
decoded.

Scanner Ready Constant dim green

The scanner is ready for operation.

Sleep Mode

Green LED slowly and 
continuously changes 
from off to dim to off.

The scanner is in Sleep Mode. To wake the 
scanner up, move an object in front of its 
window or press the button atop the unit. 
This indication is optionally configurable, 
and may have been programmed to 
behave differently.

Host Disable

Constant green flash 
at 1 Hz (100mS on, 
900mS off)

The scanner is disabled due to receiving a 
disable command from the POS terminal.

Diagnostics

Varies (see 

Error 

Codes on page 9

  for 

more information)

The LED can provide diagnostic feedback 
if the scanner discovers a problem during 
SelfTest.

Prog. Mode

Constant green flash 
at 1 Hz (500 ms on, 
500 ms off).

The scanner is in Programming Mode.

Summary of Contents for Magellan 3400VSi

Page 1: ...Magellan 3400VSi Omni Directional Imaging Scanner Quick Reference Guide...

Page 2: ...e published you can acquire printed ver sions by contacting your Datalogic representative Electronic versions may either be downloadable from the Datalogic website www datalogic com or provided on app...

Page 3: ...on 6 LED and Beeper Indicators 6 Troubleshooting 8 Error Codes 9 Programming 10 Interface Selection 10 Imaging Features 12 Camera Button Mode 12 Image Destination 13 Cell Phone Mode 14 Cell Mode Perce...

Page 4: ...ii Magellan 3400VSi NOTES...

Page 5: ...s and begin using your scanner For more details and programming information reference the Product Reference Guide PRG which is available for viewing and download from the Datalogic website www datalog...

Page 6: ...e 2 Scanner Features Back View Figure 3 Scanner Features Bottom View Cable Routing Area Serial Number Label Regulatory USB Micro B MicroSD Card Port Label USB Aux Port Power Host Port EAS Wire Cavity...

Page 7: ...t as shown in b of the illustration Scan some known good bar code samples to verify correct oper ation The scanner should beep and or flash its good read LED1 and send the bar code data to the host or...

Page 8: ...essed NOTE Volume changes made using the Scanner Button are lost when the scanner is powered down and are reset to the configured setting If you wish to permanently change the volume use the special p...

Page 9: ...nd at one of three tones Stop when the desired tone high medium or low is sounded 4 Seconds Scanner Diagnostics Modea This mode allows system sup port personnel to troubleshoot problems with the scann...

Page 10: ...Indicates the scanner has finished all its power up tests and is now ready for operation Good Read Indication Bright green flash Indicates a bar code has been read and decoded Scanner Ready Constant...

Page 11: ...ble frequency duration and volume See the Product Reference Guide PRG for more information Diagnostics Varies see Error Codes on page 9 for more infor mation The Beeper can provide diagnostic feedback...

Page 12: ...d the scanner The scanner will not read bar codes at all or reads poorly Make sure the window is clean Check that the bar codes are of sufficient quality to be recognized by the scanner Wrin kled smud...

Page 13: ...code If it is configured to do so the scanner will sound a series of beeps cor responding to the error code and or flash its LED simultaneous to the beeps The table below describes what these codes m...

Page 14: ...to scan Scan a START END bar code once to enter Programming Mode After scanning the programming label for the desired interface scan the START END barcode a second time to accept your changes exit Pr...

Page 15: ...Quick Reference Guide 11 USB OEM USB Keyboard USB COM Interface NOTE Reference the Product Reference Guide PRG or On Screen Programming for additional options START END 000145 CR 000135 CR 000147 CR...

Page 16: ...ing Features See the PRG for more information on these features Camera Button Mode Scan one of the bar codes below to enable or disable the camera button START END Camera Button Mode Disable Camera Bu...

Page 17: ...3 Image Destination Specifies the destination for pictures images taken with a cam era button press START END Image Destination Disable Image Destination SD card Image Destination Host port DEFAULT 50...

Page 18: ...14 Magellan 3400VSi Cell Phone Mode Enables disables mobile phone barcode reading START END Cell Phone Mode Disable Cell Phone Mode Enable Always On 046701 CR 046702 CR DEFAULT...

Page 19: ...de must be enabled for this to be active NOTE Settings above 10 will slow down read performance on printed barcodes START END Cell Mode Percent 2 5 Very Low Cell Mode Percent 5 Low Cell Mode Percent 1...

Page 20: ...asive mild water based cleaner to wipe away stains smudges fingerprints spills etc from the scan window and exterior surfaces See the next page for a list of Manufacturer Approved Cleaning Materials C...

Page 21: ...ombina tion with other cleaning agents will void the manufacturer s war ranty APPROVED CLEANERS Hydrogen Peroxide not to exceed a 3 solution Chlorine bleach not to exceed a 0 25 solution Mild detergen...

Page 22: ...o scrap all parts removed from the repaired product Datalogic warrants repaired hardware devices only against defects in workmanship and materials on the repaired assembly for a 90 day period starting...

Page 23: ...Datalogic such opportunity shall constitute acceptance by Buyer and waiver of all claims for defects The products must always be returned within ten 10 days from the date of authorization issued by Da...

Page 24: ...se in default under or in repudiation of this contract or any other con tract with Datalogic or fails to pay when due any invoice under this contract then in addition to any and all remedies allowed b...

Page 25: ...21 Going Green Thank you for using the bar code mask on the opposite side of this page This manual has been formatted to minimize the quantity of pages needed to provide the programming bar codes avai...

Page 26: ...page and remove it from the manual as indicated to cre ate a sleeve through which bar codes can be individually viewed and scanned It is important that only one bar code at a time be presented to the...

Page 27: ......

Page 28: ...troduced into a retrieval system or transmitted in any form or by any means or for any purpose with out the express written permission of Datalogic S p A and or its affili ates Datalogic and the Datal...

Reviews: