Interleaved 2 of 5
Product Reference Guide
5-37
Interleaved 2 of 5 — continued
Length Control
Fixed Length Decoding —
When fixed length decoding is enabled, the scanner will decode a
bar code if the label length matches one of the configurable fixed lengths.
Variable Length Decoding —
When variable length decoding is enabled, the scanner will
decode a bar code if the label length falls in the range of the configurable minimum and maxi-
mum length.
Configuring Fixed Length Decoding:
1. Scan the START bar code.
2. Scan the Fixed Length Decoding bar code.
3. Scan the END bar code.
4. Set Length 1 to the first fixed length by following the
Interleaved 2 of 5 Length 1, Length 2
Programming Instructions
below.
5. Set Length 2 to the second fixed length (or to ‘000’ if there is only one fixed length) by
following the
Interleaved 2 of 5 Length 1, Length 2 Programming Instructions
below.
Configuring Variable Length Decoding:
1. Scan the START bar code.
2. Scan the Variable Length Decoding bar code.
3. Scan the END bar code.
4. Set Length 1 to the first variable length by following the
Interleaved 2 of 5 Length 1, Length
2 Programming Instructions
below.
5. Set Length 2 to the second variable length by following the
Interleaved 2 of 5 Length 1,
Length 2 Programming Instructions
below.
START / END
PROGRAMMING BARCODES
Variable Length Decoding
DEFAULT
Fixed Length Decoding
Summary of Contents for MAGELLAN 1000I
Page 1: ...Magellan 1000i Omni Directional Imaging Scanner Product Reference Guide...
Page 12: ...Getting Started 1 6 Magellan 1000i NOTES...
Page 138: ...Symbologies 5 64 Magellan 1000i NOTES...
Page 143: ...Product Reference Guide C 1 Appendix C Alpha Numeric Pad A B C D E F...
Page 144: ...C 2 Magellan 1000i Alpha Numeric Pad 1 2 3 0 9 8 7 6 5 4...
Page 148: ...D 4 Magellan 1000i NOTES...
Page 156: ...F 2 Magellan 1000i NOTES...
Page 158: ...G 2 Magellan 1000i Sample Symbols 01 00123456789012 RSS 14 0100123456789050 RSS Expanded...