This product is covered by one or more of the following patents. 

European Patent 851,211 B1; 1,111,690 B1; 1,148,346 B1; 1,209,487 B1. 

Italian Patent IT 1,321,772. 

S5N-Px SERIES 

INSTRUCTION MANUAL 

Information on IO-Link communication is available on the last 
page of this manual. 

CONTROLS 

OUTPUT LED (S5N-

Px…B01/C01/T01) 

The yellow LED ON indicates that the NO output status is closed. 

STABILITY LED (S5N-

Px…B01/C01) 

The  green  LED  ON  indicates  that  the  received  signal  has  a  reserve 
greater than 30% compared to the output switching value. 

TRIMMER (S5N-Px

…B01/C01/T01) 

The  trimmer  can  be  used  to  adjust  sensitivity;  the  operating  distance 
increases turning the trimmer clockwise. 

WARNING: The trimmer rotation is limited to 270° by a mechanical stop. 
Do not apply excessive torque when adjusting (max 40 Nmm). 

INSTALLATION 

The sensor can be fixed by means of the M18x1 threaded body through 

  18mm  hole,  using  the  specific  washer  and  the  two  CH.24  nuts 

enclosed (1.5Nm maximum tightening torque). 
Alternatively, 

the  sensor  can  be  mounted  through  the  two  housing’s 

holes using two screws (M3x22 or longer) and washer. 
Amongst  the  various  possible  solutions,  we  suggest  to  choose  the 
combination that offers the best visibility of the signalling LEDs and the 
easiest access to the trimmer. 
Wide  range  of  accessories  available:  22mm  nuts,  h=8mm,  (2Nm 
maximum tightening torque) guarantee an improved torque and various 
orientable  fixing  brackets  ease  the  sensor 
positioning  (please  refer  to  the  accessories 
listed in the general catalogue). 
The operating distance is measured from the 
front surface of the sensor lens. 

C  models

:  To  improve  the  detection,  the 

object has to be moved closer or further away 
from the front surface of the sensor lens. 
In  case  of  lateral  translation,  the object must 
move as indicated in the figure. 

CONNECTIONS 

The connections are compliant to the EN 60947-5-2 standard. 

M12 CONNECTOR 

10 … 30 Vdc 

N.O. OUTPUT/ 
IO-Link 

0 V 

N.C. OUTPUT 

3

 

4

 

DIMENSIONS 

24

N°.2 Ø3.8

4

=

2.5

=

4

=

3.8

2

STABILITY LED

10

15

M18x

1

1.5

14

3.5

24

3.5

1.5

4

4

2

=

3.8

14

12

10

14.5

N°.2 Ø3.8

TRIMMER

15

24

4

4

1.5

12

N°.2 Ø3.8

TRIMMER

39.5

15

M18x

1

10

14

Ø

22

Ø2.2

mm

14

=

M18x

1

6.2

=

Ø4

25

25

25

RADIAL VERSION

FIBRE OPTIC VERSION

TRIMMER

OUTPUT LED

STABILITY LED

OUTPUT LED

OUTPUT LED

STABILITY LED

OUTPUT LED

STABILITY LED

without trimmer

L
X

X1

M O D E L S

with trimmer

X1

X

AXIAL VERSION

without trimmer

L
X

X1

M O D E L S

with trimmer

X

X1

CABLE VERSION

=

M12

=

M12

=

M12

14.5

L

14.5

L

79
43
46

69
42
36

57
42
24

67
43
34

72.5

14.5

10

TECHNICAL DATA 

S5N-PA AXIAL VERSION 

S5N-PR RADIAL VERSION

 

Power supply: 

10 

… 30 Vdc (limit values) 

Ripple: 

2 Vpp max. 

Current consumption  
(output current excluded): 

35 mA max. 

Outputs: 

NO and NC; PNP or NPN

 

(short-circuit protection) 

Output current: 

100 mA max.  

Output saturation voltage: 

2 V max. 

Response time: 

0.5 ms (2 ms mod.F01/G00) 

Switching frequency: 

1KHz (250 Hz mod.F01/G00) 

Indicators: 

OUTPUT LED (YELLOW) excluding mod.G00 

STABILITY LED (GREEN) (mod.B01/C01/C21/E01/F01) 

POWER ON LED (GREEN) (mod.G00) 

Setting: 

sensitivity trimmer (mod.B01/C01/C21/E01/F01/T01) 

Operating temperature: 

-

25 … 55 °C

Storage temperature: 

-

25 … 70 °C

Insulating strength: 

500 Vac 1 min., between electronics and housing 

Insulating resistance: 

>20 M

 500 Vdc, between electronics and housing

Operating distance (typical values): 

B01: 0.1

…3.5 m on R2 

C01: 0…60 cm 

T

01: 0.1…1 m on R2 

B01: 0.1…2 m on R2 

C01: 0…35 cm 

T

01: 0.1…1 m on R2 

Emission type: 

red (630 nm) (mod. E01) / red (660 nm) (mod.B01/T01) / 

infrared (880nm) (mod. C01/C21/G00) 

Ambient light rejection: 

according to EN 60947-5-2 

Vibrations: 

0.5 mm amplitude, 10 … 55 Hz frequency, for every axis (EN60068-2-6) 

Shock resistance: 

11 ms (30 G) 6 shock for every axis (EN60068-2-27) 

Housing material: 

PBT  

Lens material: 

PMMA 

Mechanical protection: 

IP67 

Connections: 

M12 - 4 pole connector 

Weight: 

25 g. max. connector vers.  

AtEx 2014/34/EU: 

I I 3G EX nA II T6 

I I 3D EX tD A22 IP67 T85°C 

SETTING 

Setting of S5N-

Px…B01/T01 

Position the sensor and reflector on opposite sides. 
Turn the sensitivity trimmer to the maximum position. 
Moving the sensor both vertically and horizontally, determine the power on and off 
points of the yellow LED (OUT) and then mount the sensor in the middle of the 
points defined. Optimum operation is obtained when the green LED (mod.B01) is 
ON and the yellow LED is OFF. 

B01 models

: If necessary reduce sensitivity in order to detect very 

small targets. In order to improve alignment, repeat the procedure 
detailed above whilst progressively reducing the sensitivity. 

T01 model

: Turn the sensitivity trimmer counterclockwise until the 

yellow  LED  turns  ON 

(pos.A). 

Turn  slowly  the  trimmer again clockwise until the 

yellow LED turns OFF 

(Operating condition, pos.B). 

Setting of S5N-

Px…C01 

Turn the sensitivity trimmer to minimum: the green LED is ON, the yellow LED is 
OFF. Position the target to detect in front of the sensor or of the fibre terminals. 
Turn  the  sensitivity  trimmer  clockwise  until  the  yellow  LED  turns  ON 

(Target 

detected state, pos.A). 

Remove the target, the yellow LED turns OFF. 
Turn the sensitivity trimmer clockwise until the yellow LED turns ON 

(Background 

detected state, pos.B). 

The trimmer reaches maximum if the background is not detected. 
Turn the trimmer to the intermediate position C, between the two positions A and 
B. The green LED must be ON. 

Datalogic S.r.l. 

Via S. Vitalino 13 - 40012 Calderara di Reno - Italy 
Tel: +39 051 3147011 - Fax: +39 051 3147205 - www.datalogic.com

 

Helpful  links  at  www.datalogic.com: 

Contact  Us,

 

Terms  and  Conditions,

 

Support

The warranty period for this product is 36 months. See General Terms and 
Conditions of Sales for further details. 

For information about the disposal of Waste Electrical 
and Electronic Equipment (WEEE), please refer to the 
website a

www.datalogic.com

 

©  2007  -  2019  Datalogic  S.p.A.  and/or  its  affiliates 

  ALL  RIGHTS 

RESERVED 

  Without  limiting  the  rights  under  copyright,  no  part  of  this 

documentation  may  be  reproduced,  stored  in  or  introduced  into  a  retrieval 
system,  or  transmitted  in  any  form  or  by  any  means,  or  for  any  purpose, 
without  the  express  written  permission  of  Datalogic  S.p.A.  and/or  its 
affiliates.  Datalogic  and  the  Datalogic  logo  are  registered  trademarks  of 
Datalogic  S.p.A.  in  many  countries,  including  the  U.S.A.  and  the  E.U.  All 
other  trademarks  and  brands  are  property  of  their  respective  owners. 
Datalogic  reserves  the  right  to  make  modifications  and  improvements 
without prior notification. 

82100632

1

 Rev. 

B

 

MIN 

MAX 

Summary of Contents for IO-Link S5N-P Series

Page 1: ...perature 25 70 C Insulating strength 500 Vac 1 min between electronics and housing Insulating resistance 20 M 500 Vdc between electronics and housing Operating distance typical values B01 0 1 3 5 m on...

Page 2: ...5 70 C Rigidit dielettrica 500 Vca 1 min tra parti elettroniche e contenitore Resistenza d isolamento 20 M 500 Vcc tra parti elettroniche e contenitore Distanza operativa valori tipici B01 0 1 3 5 m s...

Page 3: ...und Geh use Isolationswiderstand 20 M 500 Vdc zwischen elektronischen Teilen und Geh use Reich Tastweiten typische Werte B01 0 1 3 5 m gegen R2 C01 0 60 cm T01 0 1 1 m gegen R2 B01 0 1 2 m gegen R2 C0...

Page 4: ...que 500 Vca 1 min entre composants lectroniques et bo tier R sistance d isolement 20 M 500 Vcc entre composants lectroniques et bo tier Distance de d tection valeurs typiques B01 0 1 3 5 m sur R2 C01...

Page 5: ...e Description Data Type Access 0x000C 12 Device Access Locks 2 octets Bit 0 Parameter write access 0 unlocked 1 locked Bit 1 Data Storage 0 unlocked 1 locked Standardized Device locking functions Bit...

Page 6: ...ic RO 0x0029 41 Process Data Output 1 octet Read last valid Process Data Output from PDout channel Device specific RO 0x0052 82 Device Temperature 2 octets 2 octets 2 octets 2 octets 2 octets 1 64 2 4...

Page 7: ...0 High Active default B01 T01 0x01 Low Active default C01 0x01 Single Point default DO pin configuration UIntegerT UIntegerT R W Saved in non volatile memory 2 octets 3 0 Not used M03 0 10 Hysteresis...

Page 8: ...Warning Out of specification only B01 C01 T01 0x4210 16912 Temperature overrun Appears Disappears Warning Out of specification 0x5100 20736 General power supply fault Appears Disappears Error Failure...

Page 9: ...ergreifen FR Conformit CE La marque CE indique la conformit du produit aux exigences essentielles nonc es dans la directive europ enne applicable Les directives et les normes applicables sont sujette...