Enter/Exit Programming Mode
2D Global Features
202
Heron™ HD3430
2D Maximum Decoding Time
This feature specifies the maximum amount of time the software will spend
attempting to decode a 2D label. The selectable range is 10 milliseconds to
2.55 milliseconds.
$CDETM0A(CR)
2D Maximum Decoding Time = 100 msec
$CDETM32(CR)
2D Maximum Decoding Time = 200 msec
$CDETM23(CR)
2D Maximum Decoding Time = 350 msec
DEFAULT
$CDETM80(CR)
2D Maximum Decoding Time = 500 msec
$CDETM16(CR)
2D Maximum Decoding Time = 1 Second
$CDETMC8(CR)
2D Maximum Decoding Time = 2 Seconds
$CDETMFF(CR)
2D Maximum Decoding Time = 2.55 Seconds