Enter/Exit Programming Mode
2D Global Features
202
Gryphon™ I GD44XX
/
GBT4400/GM440X
2D Maximum Decoding Time
This feature specifies the maximum amount of time the software will spend attempting to
decode a 2D label. The selectable range is 10 milliseconds to 2.55 milliseconds.
2D Maximum Decoding Time = 100 msec
2D Maximum Decoding Time = 200 msec
2D Maximum Decoding Time = 350 msec
2D Maximum Decoding Time = 500 msec
2D Maximum Decoding Time = 1 Second
2D Maximum Decoding Time = 2 Seconds
2D Maximum Decoding Time = 2.55 Seconds
$CDETM0A(CR)
$CDETM32(CR)
$CDETM23(CR)
DEFAULT
$CDETM80(CR)
$CDETM16(CR)
$CDETMC8(CR)
$CDETMFF(CR)