Enter/Exit Programming Mode
GS1-128
148
Gryphon™ I GD44XX
/
GBT4400/GM440X
GS1-128
The following options apply to the GS1-128 symbology. (Also known as USS-128, GS1-128,
GTIN-128, UCC-128, EAN-128.)
GS1-128 Enable
This option enables/disables the ability of the reader to translate GS1-128 labels to the GS1-128
data format. Options are:
•
Transmit GS1-128 labels in Code 128 data format.
•
Transmit GS1-128 labels in GS1-128 data format.
•
Do not transmit GS1-128 labels.
GS1-128 2D Component
This feature enables/disables a requirement that a 2D label component be decoded when a base
label of this symbology is decoded.
GS1-128 = Transmit in Code 128 data format
GS1-128 = Transmit in GS1-128 data format
GS1-128 = Do not transmit GS1-128 labels
$CU8EN00CR)
$CU8EN01CR)
DEFAULT
$CU8EN02CR)
GS1-128 2D Component = Disable
GS1-128 2D Component = Enable
DEFAULT
$CU82D00(CR)
$CU82D01(CR)