References
250
Gryphon™ I GD44XX
/
GBT4400
ACK Character
This setting specifies an ASCII character or hex value to be used as the ACK character. ASCII
characters or any hex value from 0 to 0xFF can be selected.
Setting to previously defined characters such as XON, XOFF, or host com-
mands conflicts with normal operation of these characters. 8-bit data is not
recognized when the option
has been set as 7 Data Bits.
1. Determine the desired character or value.
2. Use the
on the inside back cover of this manual to find the hex equivalent
for the desired character/value.
3. Go to
and scan ENTER/EXIT PROGRAMMING MODE to enter Program-
ming Mode.
4. Scan the bar code: SELECT ACK CHARACTER SETTING.
5. Scan the appropriate two alphanumeric characters from the keypad in
, that represent the desired character/value in step 1 above. The second character will
cause a two-beep indication.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit.
See
for some examples of how to set this feature.
Table 26. ACK Character Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Character/Value
ACK
$
@
>
2
Hex equivalent from
0x06
0x24
0x40
0x3E
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT ACK CHARACTER SETTING
5
Scan Two Characters from
‘0’ and ‘6’
‘2’ and ‘4’
‘4’ and ‘0’
‘3’ AND ‘E’
6
Scan ENTER/EXIT PROGRAMMING MODE
Summary of Contents for Gryphon I GD44XX
Page 40: ...Enter Exit Programming Mode 38 Gryphon I GD44XX GBT4400 NOTES...
Page 54: ...Enter Exit Programming Mode 52 Gryphon I GD44XX GBT4400 NOTES...
Page 63: ...Product Reference Guide 61...
Page 64: ...62 Gryphon I GD44XX GBT4400...
Page 232: ...228 Gryphon I GD44XX GBT4400 NOTES...
Page 294: ...290 Gryphon I GD44XX GBT4400 NOTES...
Page 312: ...308 Gryphon I GD44XX GBT4400 A B C D E F...
Page 322: ...318 Gryphon I GD44XX GBT4400 NOTES...