ENTER/EXIT PROGRAMMING MODE
Product Reference Guide
253
CODE 4
The following options apply to the Code 4 symbology.
Code 4 Enable/Disable
Enables/Disables ability of imager to decode Code 4 labels.
DEFAULT
Code 4 = Disable
Code 4 = Enable
Code 4 Check Character Transmission
This feature enables/disables transmission of an optional Code 4 check charac-
ter.
Code 4 Check Character Transmission = Don’t Send
Code 4 Check Character Transmission = Send
DEFAULT
Summary of Contents for Gryphon I GD4132
Page 18: ...Introduction 16 Gryphon I GD4132 GM4102 GBT4102 NOTES...
Page 40: ...Setup 38 Gryphon I GD4132 GM4102 GBT 4102 NOTES...
Page 44: ...Configuration Using Barcodes 42 Gryphon I GD4132 GM4102 GBT 4102 NOTES...
Page 260: ...ENTER EXIT PROGRAMMING MODE 258 Gryphon I GD4132 GM4102 GBT4102 NOTES...
Page 324: ...Technical Specifications 322 Gryphon I GD4132 GM4102 GBT4102 NOTES...
Page 341: ...Product Reference Guide 339 A B C D E F...
Page 342: ...Keypad 340 Gryphon I GD4132 GM4102 GBT4102 NOTES...
Page 352: ...Scancode Tables 350 Gryphon I GD4132 GM4102 GBT4102 NOTES...