Technical Specifications

QUICK REFERENCE GUIDE   

29

Output connection - Typical layout

Figure 8. NPN output configuration

Figure 9. PNP output configuration

ENTER/EXIT PROGRAMMING MODE

★ 

NPN configuration = Set Output Configuration to NPN

PNP configuration = Set Output Configuration to PNP

GFS4550 / GFE4590

USER INTERFACE

NPN Output Connection

Load

Vext [14V max.]

VDC

GFS4550 / GFE4590

USER INTERFACE

PNP Output Connection

Load

Summary of Contents for Gryphon GFS4500

Page 1: ...Gryphon I GFS4500 QUICK REFERENCE GUIDE Fixed Mount Area Imager Bar Code Reader...

Page 2: ...y be downloaded from the Data logic website www datalogic com If you visit our website and would like to make comments or suggestions about this or other Datalogic publica tions please let us know via...

Page 3: ...Other Settings 16 Resetting Product Defaults 16 NUMLOCK 17 Reading Parameters 18 Aiming System 18 Good Read Green Spot Duration 18 Operating Modes 19 Pick Mode 21 Multiple Label Reading 21 Energy Sav...

Page 4: ...Contents IV GRYPHON I GBT GM4500 Support Through the Website 38 Reseller Technical Support 38...

Page 5: ...machine readable form only solely for End User s internal business purposes 1 2 End Users shall not distribute sublicense rent loan lease assign export re export resell ship or divert or cause to be e...

Page 6: ...termination shall be effective upon notice to the other party In the event that this Agreement terminates for any rea son End User s license to use the Software will immediately terminate and End User...

Page 7: ...other items not provided by Datalogic 7 Support End User may request support for Software from Datalogic at Datalogic s standard support fees and under Datalogic s standard support terms and conditio...

Page 8: ...which Open Source Software packages have source code provided or avail able 11 Notices All notices required or authorized under this Agreement shall be given in writing and shall be effective when re...

Page 9: ...lidity interpretation and construction of the Agreement shall be governed by and construed in accordance with Laws of the Republic of Sin gapore Parties expressly disclaim the application of the Unite...

Page 10: ...customers with the very latest in Datalogic soft ware technology The only exception to this policy is when the buyer has a signed contract with Datalogic that clearly defines the terms and conditions...

Page 11: ...ating temperature and the great resistance to accidental drops shock and vibrations RS 232 and USB RS 232 models have an integrated cable while the USB models are equipped with a locking clip to preve...

Page 12: ...lable in the following data interface versions 1 GFS4520 USB micro USB connector 2 GFS4550 RS232 2m straight cable DB9 connector 3 GFS4590 USB RS232 10cm multi interface connec tor SETTING UP THE READ...

Page 13: ...Setting Up the Reader QUICK REFERENCE GUIDE 3 Parts of the Reader 1 Power Status LEDs 2 Scan window 3 Beeper output 4 Trigger 5 USB cable retainer only for GFS4520 4 1 2 3 5 GFS4520 model...

Page 14: ...of its housing 2 Rotate the retainer clockwise and insert the USB cable 3 Set back the retainer by rotating it counterclockwise and push until the cable is firmly locked NOTE Different microUSB cable...

Page 15: ...Setting Up the Reader QUICK REFERENCE GUIDE 5 Video Tutorial 2 3...

Page 16: ...e Follow the steps indicated by the pictures below to con nect the reader to the Host according to the communica tion cable available NOTE Refer to the Product Reference Guide for the list of compatib...

Page 17: ...r is equipped with an inter nal Motionix motion sensing function which activates the aiming system on device motion The intelligent aim ing system indicates the field of view which should be positione...

Page 18: ...with smaller bars or elements mil size should be read closer to the unit Symbologies with larger bars or elements mil size should be read farther from the unit If the aiming system is centered you wil...

Page 19: ...de to select your system s correct interface type according to your application For interfaces other than those listed in this manual see the Gryphon I GFS4500 Product Reference Guide PRG available on...

Page 20: ...ctly to a USB host or a powered USB hub and is powered by it No additional power supply is required The reader auto detects the USB and defaults to the USB COM interface USB KBD Select USB KBD To simu...

Page 21: ...elect USB COMa Simulate a serial interface a Download the correct USB COM driver from https www datalogic com USB COMPOSITE Select USB Composite Combines USB KBD emulation and USB COM USB OEM Refer to...

Page 22: ...Mode This feature specifies the country language supported by the keyboard Several languages are supported COUNTRY MODE ENTER EXIT PROGRAMMING MODE Country Mode U S Country Mode Belgium Country Mode...

Page 23: ...ace Type QUICK REFERENCE GUIDE 13 COUNTRY MODE CONTINUED Country Mode France Country Mode French Canadian Country Mode Germany Country Mode Hungary Country Mode Italy Country Mode Japanese 106 key Cou...

Page 24: ...g the Interface Type 14 GRYPHON I GFS4500 COUNTRY MODE CONTINUED Country Mode Norway Country Mode Poland Country Mode Portugal Country Mode Romania Country Mode Slovakia Country Mode Spain Country Mod...

Page 25: ...platform utility program allows device configuration using a PC It communicates with the device using a serial or USB cable and can also create con figuration barcodes to print Using Programming Bar...

Page 26: ...sure what programming options have been set in your reader or you have changed some options and want your custom factory settings restored scan the bar code below to reset the reader to its initial co...

Page 27: ...the setting of the Numbers Lock Numlock key while in keyboard wedge interface This only applies to alternate key encoding interfaces It does not apply to USB keyboard NUMLOCK ENTER EXIT PROGRAMMING M...

Page 28: ...cquisition The illuminator will remain on until the symbol is decoded Aiming System A number of options for customizing control of the Aiming System are available See the Gryphon I GFS4500 PRG for mor...

Page 29: ...nning is continually on Object Sense2 Scanning is turned on automatically when an item is placed in reader s field of view Test mode Once entered the Status LED is activated in different colors depend...

Page 30: ...ting Modes 20 GRYPHON I GFS4500 OPERATING MODE ENTER EXIT PROGRAMMING MODE Operating Mode On Line Operating Mode Serial On Line Operating Mode Alway On Operating Mode Object Sense Operating Mode Test...

Page 31: ...of the aiming pattern are not acknowledged or transmitted to the host If the scanner switches to a differ ent Read Mode Pick Mode is automatically disabled default value MULTIPLE LABEL READING The rea...

Page 32: ...t and Aimer LEDs is reduced to Mid level Energy Saving Max Volume of Good Read Beep is reduced to Low Level Intensity of Green Spot and Aimer LEDs is reduced to Low level Intensity of Status and Power...

Page 33: ...nner can be configured to match different perfor mance needs depending on the application The following barcodes contain predefined configurations to be applied ENERGY SAVING TYPICAL POWER SAVING Off...

Page 34: ...TICS Current Operating Typical 225 mA Standby Idle Typical Automatic Object Sense Mode 115 mA Online Serial Online Modes 55 mA Input Voltage GFS4520 5 VDC 5 GFS4550 GFS4590 GFE4590 5 14 VDC ENVIRONMEN...

Page 35: ...Data Matrix 10 mil 3 5 to 23 5 cm 1 3 to 9 6 in 15 mil 3 0 to 35 0 cm 1 2 to 13 7 in EAN UPC 13 mil 4 0 to 82 0 cm 1 6 to 32 3 in PDF417 10 mil 1 5 to 35 0 cm 5 9 to 13 7 in QR Code 10 mil 3 5 to 22 0...

Page 36: ...NAK disabled 9 PIN CONNECTOR 1 Trigger Trigger signal input see Figure 5 and Figure 6 on next page 2 TX Transmit Data output from scanner 3 RX Receive Data input to scanner 4 NC Not connected 5 GND Gr...

Page 37: ...Technical Specifications QUICK REFERENCE GUIDE 27 Input connection Typical layout Figure 5 NPN configuration ENTER EXIT PROGRAMMING MODE NPN configuration Set Input Configuration to NPN...

Page 38: ...500 Figure 6 PNP configuration Figure 7 NPN or PNP configuration Ensure both sides are configured the same way PNP configuration Set Input Configuration to PNP Vext 5 0 Vdc to 14 0 Vdc I_IN 4 0 mA max...

Page 39: ...figuration Figure 9 PNP output configuration ENTER EXIT PROGRAMMING MODE NPN configuration Set Output Configuration to NPN PNP configuration Set Output Configuration to PNP GFS4550 GFE4590 USER INTERF...

Page 40: ...Technical Specifications 30 GRYPHON I GFS4500 GFS4500 Dimensions...

Page 41: ...r may not be turned on For example certain indications such as the power up beep can be disabled using programming bar code labels POWER LED green ON Power ON Blinking USB enumera tion USB version onl...

Page 42: ...reen LED comes on for pro grammed time default LED behavior for this indication is configu rable using Aladdin utility One beep at current frequency volume mono bi tonal setting upon a successful labe...

Page 43: ...ar code type Ensure reader is pro grammed to read the type of bar code scanned Refer to the PRG for more informa tion Bar code label is unreadable Check the label to ensure it is not defaced Try to sc...

Page 44: ...GFS4400 family with the new Gry phonTM I GFS4500 Since the two products have different mounting holes the Adapter Plate can be attached to the GFS4500 to replicate the same mounting holes of the pre...

Page 45: ...FERENCE GUIDE 35 Figure 10 Comparison of front views of Gryphon GFS4400 left and Gryphon GFS4500 with Mounting Adapter right Figure 11 Comparison of bottom views of Gryphon GFS4400 left and Gryphon GF...

Page 46: ...ole unit consumable items 7 use of counterfeit or replacement parts that are neither manu factured nor approved by Datalogic for use in Datalogic manufactured Products 8 any damage or malfunctioning c...

Page 47: ...orrect heights Reduce or eliminate vibration Reduce or eliminate direct pressure Provide adjustable workstations Provide adequate clearance Provide a suitable working environment Improve work procedur...