Technical Specifications
24
Gryphon™ GFE4400
Error Codes
Upon startup, if the reader’s LED2 and Green Spot are blinking alternate-
ly, this means the reader has not passed its automatic Selftest and has en-
tered FRU (Field Replaceable Unit) isolation mode. If the reader is reset,
the sequence will be repeated. Press and release the trigger to see the FRU
indication code from LED2 flashes.
The following table describes the LED flashes associated with an error
found.
Number of LED2
Flashes
Error
Corrective Action
1
Configuration
Contact Helpdesk
for assistance
2
Interface PCB
6
Digital PCB
11
Imager
Summary of Contents for Gryphon GFE4400