Technical Specifications
26
GRYPHON™ I GD4200
READING PARAMETERS
DOF
a
a. The depth of field is defined by an arc and not a plane. Shorter bar codes of a given
resolution can be read at a further distance than longer bar codes (as explained in
the image below).
Code 39 5mils: 50 to 370mm / 1.97 to 14.6 inch
b
b. All labels grade A, typical environmental light, 20°C, label inclination 10°.
Code 39 7.5mils: 50 to 540mm / 1.97 to 21.3 inch
b
Code 39 10mils: 50 to 735mm / 1.97 to 28.9inch
b
Code 39 20mils: 25 to 1470mm / 0.98 to 57.87 inch
b
EAN13 13 mils: 35 to 900mm / 1.38 to 35.43 inch
b
Resolution
(Maximum)
0.0077mm /3mils