LED and Beeper Indicators
Product Reference Guide
45
Good Read LED Duration
This feature specifies the amount of time that the Good Read LED remains on following a good
read. The good read LED on time can be set within a range of 10 milliseconds to 2,550
milliseconds (0.001 to 2.55 seconds) in 100ms increments.
Follow these instructions to set this feature:
1. Determine the desired setting in milliseconds. A setting of 0 means that the good read
LED stays on until the next time the trigger is pulled.
2. Divide the desired setting by 10 (setting is in 100ms increments). Pad the result with lead-
ing zeroes to yield three digits. For example: 0 = 000, 5 = 000, 20 = 020, etc.
3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming
Mode.
4. Scan the barcode: SELECT GOOD READ LED DURATION SETTING.
5. Scan the appropriate three digits from the keypad in Appendix E, Keypad representing the
duration which was determined in the steps above. You will hear a two-beep indication
after the last character.
NOTE
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
Mode.
This completes the procedure. See Table
for some examples of how to set this feature.
Table 2. Good Read LED Duration Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
Good Read LED
stays on until
next trigger pull
(00)
20ms
150ms
2550ms (2.55 sec.)
2
Divide by 10 (and pad with
leading zeroes)
000
002
015
255
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT LABEL GONE TIMEOUT SETTING
5
Scan Three Characters
From
‘0’, ‘0’ and ‘0’
‘0’, ‘0’ and ‘2’
‘0’, ‘1’ and ‘5’
‘2’, ‘5’ and ‘5’
6
Scan ENTER/EXIT PROGRAMMING MODE
If you make a mistake before the last character, scan the CANCEL
barcode to abort and not save the entry string. You can then start
again at the beginning.
Summary of Contents for Gryphon GD4100
Page 14: ...Introduction 12 Gryphon I GD4100 GM4100 NOTES ...
Page 34: ...Getting Started 32 Gryphon I GD4100 GM4100 NOTES ...
Page 68: ...General Features 66 Gryphon I GD4100 GM4100 NOTES ...
Page 80: ...RS 232 ONLY Interface 78 Gryphon I GD4100 GM4100 NOTES ...
Page 100: ...RS 232 USB Com Interfaces 98 Gryphon I GD4100 GM4100 NOTES ...
Page 118: ...USB OEM Interface 116 Gryphon I GD4100 GM4100 NOTES ...
Page 130: ...Wand Emulation Interface 128 Gryphon I GD4100 GM4100 NOTES ...
Page 154: ...Data Editing 152 Gryphon I GD4100 GM4100 NOTES ...
Page 392: ...LED and Beeper Indications 390 Gryphon I GD4100 GM4100 NOTES ...
Page 408: ...Sample Barcodes 406 Gryphon I GD4100 GM4100 NOTES ...
Page 410: ...Keypad 408 Gryphon I GD4100 GM4100 6 7 8 9 ...
Page 411: ...Keypad Product Reference Guide 409 A B C D E F ...
Page 412: ...Keypad 410 Gryphon I GD4100 GM4100 NOTES ...
Page 422: ...420 Gryphon I GD4100 GM4100 IBM XT Table 60 Scancode Set When Control Character is 00 or 01 ...
Page 423: ...Product Reference Guide 421 IBM XT cont Table 61 Scancode Set When Control Character is 02 ...