HOST CONFIGURATION STRINGS
A
A
HOST CONFIGURATION STRINGS
In this section we provide a description of how to modify the device configuration
using serial strings sent from the Host.
This method requires the RS232 interface.
The device configuration can be changed by receiving commands from the Host
through the serial interface. When this method is used, the programming sequence
format is the following:
Command
Character sequence in following tables
CR
$-
$+
Carriage return character (0D Hex.)
Enter configuration environment
Exit and Save configuration
Example:
Beeper tone 1
Beeper low intensity
BG1
$-
CR
Carriage return character (0D Hex.)
Exit and save new configuration
AC410132
BH0
Matrix 2/5 3 bars: no check digit,
variable length code from 1 to 32 characters
$+
Enter configuration environment
Multiple command programming sequence:
Each configuration parameter setting removes the condition previously active for that
parameter.
NOTE
The device buffer can contain about 400 characters. If your
programming string goes over this value, you must split it into separate
groups and send each group after a delay of at least 3 seconds to give
the reader time to empty the buffer and interpret the commands.
169
Summary of Contents for Gryphon DX30
Page 1: ...GRYPHON Dx30 Mx30 Reference Manual 90ACC1930 ...
Page 2: ......
Page 3: ...GRYPHON Dx30 Mx30 REFERENCE MANUAL ...
Page 14: ...GRYPHON Dx30 Mx30 2 2 3 RS232 CONNECTION 2 4 USB if required 4 ...
Page 15: ...INSTALLATION 2 2 5 IBM USB POS 2 6 WEDGE CONNECTION 5 ...
Page 16: ...GRYPHON Dx30 Mx30 2 6 ...
Page 17: ...INSTALLATION 2 2 7 PEN EMULATION CONNECTION 7 ...
Page 195: ...CODE IDENTIFIER TABLE B 185 ...
Page 197: ...HEX AND NUMERIC TABLE 187 C OPEN THIS PAGE TO READ THE DESIRED HEX AND NUMERIC SELECTIONS ...
Page 199: ...GRYPHON Dx30 Mx30 Reference Manual 90ACC1930 ...