DEFAULT VALUES
RS232 Standard DEFAULT SETTINGS
9600 baud, no parity, 8 data bits, 1 stop bit, no handshaking, delay disabled, rx
timeout 5 sec., ack/nack disabled, FIFO enabled.
DATA FORMAT
: code identifier disabled, no field adjustment, code length not
transmitted,
no header
,
terminator = CR-LF
, character replacement disabled.
IBM 46xx DEFAULT SETTINGS
DATA FORMAT
: IBM Standard, code identifier disabled,
no header
, no
terminator.
POWER SAVE
scan rate 270scans/s, standby disabled, sleep state disabled.
READING PARAMETERS
operating mode hand-held, hardware trigger, trigger active level, no trigger-
off timeout, Flash On = 1 sec, Flash Off = .6 sec, one read per cycle, safety
time .5 sec, beeper intensity high, tone 2, beeper type monotone, beeper
length short, good read spot duration medium.
DECODING PARAMETERS
ink spread enabled, overflow control enabled, interdigit control enabled,
Puzzle Solver™ disabled, decoding safety = one read.
CODE SELECTION
Enabled codes
•
EAN 8/EAN 13 / UPC A/UPC E without ADD ON
check digit transmitted, no conversions
•
Interleaved 2/5
check digit control and transmission, variable length code; 4-99
characters
•
Standard Code 39
no check digit control, variable length code; 1-99 characters
•
Code 128
variable length code; 1-99 characters
Disabled codes
EAN 128, ISBT128, Code 93, Codabar, pharmaceutical codes, MSI,
Plessey, Telepen, Delta IBM, Code 11, Code 16K, Code 49, RSS Codes
ADVANCED FORMATTING PARAMETERS*
concatenation disabled, no advanced formats defined.
*The advanced formatting parameters may not be compatible with the IBM 46xx
cash register parameters.
TECHNICAL FEATURES
Gryphon
™
D110
Electrical Features
Power Supply
RS232 interface
IBM 46xx
5 Vdc
±
5%
directly taken from cash register
Consumption:
Maximum
Operating
Sleep mode/USB Suspend
330 mA @ 5 Vdc
250 mA @ 5 Vdc
<500
μ
A @ 5 Vdc
Max. Scan Rate
270 scans/sec
Reading Indicators
LED, Good Read Spot, Beeper
Optical Features
Sensor
CCD solid state (3648 pixels)
Illuminator LED
array
Wavelength
630 ~ 670 nm
Max. LED Output Power
0.33 mW
LED Safety Class
Class 1 EN 60825-1
Reading Field
see reading diagram
Max. Resolution
0.076 mm (3 mils)
PCS (Datalogic Test Chart)
min. 15%
Environmental Features
Working Temperature
0
°
C to + 55
°
C
Storage Temperature
-20
°
C to + 70
°
C
Humidity 90%
non
condensing
Drop Resistance
IEC 68-2-32 Test ED
ESD Protection
16 kV
Protection Class
IP30
Mechanical Features
Weight (without cable)
about 200 g (7 oz)
Cable Length
2 m (6 ft 6 in)
RESTORE DEFAULT
RESTORE DEFAULT
Ì$+$*oÎ
To change the defaults refer to the “Gryphon™ Reference Manual”, part number
90ACC1780
, or to the Configuration program, both downloadable from the
website.
INTERFACE SELECTION
Select one of the interface codes according to your application.
RS232 INTERFACE SELECTION
RS232 Standard
Ì$+CP0$-$Î
IBM 46XX TERMINALS
PORT 9B
4501 Protocol
Ì$+CP800$-pÎ
(typical)
1520
Protocol
Ì$+CP801$-wÎ
PORT 5B
1520 Protocol
Ì$+CP801$-wÎ
(typical)
4501
Protocol
Ì$+CP800$-pÎ
OPERATING TEST
Read the test codes below.
EAN-8
1 2 3 4 5 6 7 0
EAN-13
1 2 3 4 5 6 7 0 0 0 9 9 2
Code 39 (Normal)
1
7
1
6
2
Code 128
t
e
s
t
Interleaved 2 of 5
0 1 2 3 4 5 6 7 8 4
IBM DATA FORMATTING
To select the data formatting for these IBM Terminals, read one of the code
selections below. (default = IBM Standard).
Conversion to Code 39
Ì$+GD0$-gÎ
IBM Standard
Ì$+GD1$-lÎ
Mixed IBM St Code 39
Ì$+GD2$-qÎ
IBM DATA FORMATTING (TRANSMISSION FORMAT)
The IBM 46xx Series cash register recognizes the following codes:
EAN 8 / EAN13 / UPC A / UPC E with and without Add On
Interleaved 2/5
Code 39
Codabar
Code 128
Code 93
Normal 2/5
The transmission format of codes belonging to this set is specified by the protocol.
As the reader allows a wider set of codes to be selected, the following formats are
defined to offer the user all the reading possibilities of the Datalogic product.
Conversion to Code 39 Format
Data from any code selected may be transmitted. Each code is transmitted to the
Host as Code 39. Any character not included in the standard Code 39 set will be
replaced with a “Space” (20 Hex).
IBM Standard Format (default)
Only codes belonging to the above mentioned set may be transmitted. Each code
transmitted to the Host is recognized by the identifier requested by the protocol. If
the selected code does not belong to this set, it wiII not be transmitted.
MIXED IBM St Code 39 Format
Data from any code selected may be transmitted. For codes belonging to the
above-mentioned set, the “IBM Standard Format” is applied. The “Code 39’ Format
applies to codes not belonging to this set.
USING GRYPHON
™
D110 READERS
Gryphon
™
guns automatically scan barcodes
at a distance
. Simply aim and pull
the trigger. Code scanning is performed along the center of the light bar emitted
from the reading window. This bar must cover the entire code.
Successful scanning is obtained by tilting the scanner with respect to the barcode
to avoid direct reflections, which impair the reading performance, see the figure
above.
Successful reading is obtained by an audible tone plus a