background image

DEFAULT VALUES 

 

RS232 Standard DEFAULT SETTINGS 

9600 baud, no parity, 8 data bits, 1 stop bit, no handshaking, delay disabled, rx 
timeout 5 sec., ack/nack disabled, FIFO enabled. 

DATA FORMAT

: code identifier disabled, no field adjustment, code length not 

transmitted, 

no header

terminator = CR-LF

, character replacement disabled. 

IBM 46xx DEFAULT SETTINGS

 

DATA FORMAT

: IBM Standard, code identifier disabled, 

no header

, no 

terminator.

 

POWER SAVE 

scan rate 270scans/s, standby disabled, sleep state disabled. 

READING PARAMETERS 

operating mode hand-held, hardware trigger, trigger active level, no trigger-
off timeout, Flash On = 1 sec, Flash Off = .6 sec, one read per cycle, safety 
time .5 sec, beeper intensity high, tone 2, beeper type monotone, beeper 
length short, good read spot duration medium. 

DECODING PARAMETERS 

ink spread enabled, overflow control enabled, interdigit control enabled, 
Puzzle Solver™ disabled, decoding safety = one read. 

CODE SELECTION 

Enabled codes

 

EAN 8/EAN 13 / UPC A/UPC E without ADD ON 
check digit transmitted, no conversions 

 

Interleaved 2/5 
check digit control and transmission, variable length code; 4-99 
characters 

 

Standard Code 39 
no check digit control, variable length code; 1-99 characters 

 

Code 128 
variable length code; 1-99 characters 

Disabled codes

EAN 128, ISBT128, Code 93, Codabar, pharmaceutical codes, MSI, 
Plessey, Telepen, Delta IBM, Code 11, Code 16K, Code 49, RSS Codes

 

ADVANCED FORMATTING PARAMETERS* 

concatenation disabled, no advanced formats defined.

 

 
*The advanced formatting parameters may not be compatible with the IBM 46xx
cash register parameters. 
 

 
 

TECHNICAL FEATURES 

 

Gryphon

 D110 

 

Electrical Features 

Power Supply 

RS232 interface 
IBM 46xx 

 

5 Vdc 

±

 5% 

directly taken from cash register 

Consumption: 

Maximum 
Operating 
Sleep mode/USB Suspend 

 

330 mA @ 5 Vdc 
250 mA @ 5 Vdc 

<500 

μ

A @ 5 Vdc 

Max. Scan Rate 

270 scans/sec 

Reading Indicators 

LED, Good Read Spot, Beeper 

Optical Features 

Sensor 

CCD solid state (3648 pixels) 

Illuminator LED 

array 

Wavelength 

630 ~ 670 nm 

Max. LED Output Power 

0.33 mW 

LED Safety Class 

Class 1 EN 60825-1 

Reading Field 

see reading diagram 

Max. Resolution 

0.076 mm (3 mils) 

PCS (Datalogic Test Chart) 

min. 15% 

Environmental Features 

Working Temperature 

°

C to + 55 

°

Storage Temperature 

-20 

°

C to + 70 

°

Humidity 90% 

non 

condensing 

Drop Resistance 

IEC 68-2-32 Test ED 

ESD Protection 

16 kV 

Protection Class 

IP30 

Mechanical Features 

Weight (without cable) 

about 200 g (7 oz) 

Cable Length 

2 m (6 ft 6 in) 

 

 

RESTORE DEFAULT 

 

RESTORE DEFAULT 

Ì$+$*oΠ

 
To change the defaults refer to the “Gryphon™ Reference Manual”, part number

90ACC1780

, or to the Configuration program, both downloadable from the 

website. 
 
 
 

INTERFACE SELECTION 

 
Select one of the interface codes according to your application. 
 

RS232 INTERFACE SELECTION 

 

RS232 Standard 

Ì$+CP0$-$Π

 
 

IBM 46XX TERMINALS 

 

PORT 9B 

4501 Protocol 

Ì$+CP800$-pΠ

(typical) 

 

 

 

 1520 

Protocol 

Ì$+CP801$-wΠ

PORT 5B 

1520 Protocol 

Ì$+CP801$-wΠ

(typical) 

 

 

  

4501 

Protocol 

Ì$+CP800$-pΠ

 

 
 

OPERATING TEST 

 
Read the test codes below. 
 
 

EAN-8 

    1 2 3 4   5 6 7 0    

 

 
 

EAN-13 

1   2 3 4 5 6 7   0 0 0 9 9 2    

 

 
 

Code 39 (Normal) 

1

7

1

6

2

 

 
 

Code 128 

t

e

s

t

 

 
 

Interleaved 2 of 5 

0 1 2 3 4 5 6 7 8 4

 

 

IBM DATA FORMATTING 

 
To select the data formatting for these IBM Terminals, read one of the code 
selections below. (default = IBM Standard). 
 
 

Conversion to Code 39 

Ì$+GD0$-gÎ

 

‹

 IBM Standard 

Ì$+GD1$-lÎ

 

Mixed IBM St Code 39 

Ì$+GD2$-qÎ

 

 
 

 

 
 

IBM DATA FORMATTING (TRANSMISSION FORMAT) 

 
The IBM 46xx Series cash register recognizes the following codes: 
 
EAN 8 / EAN13 / UPC A / UPC E with and without Add On 
Interleaved 2/5 
Code 39 
Codabar 
Code 128 
Code 93 
Normal 2/5 
 
The transmission format of codes belonging to this set is specified by the protocol. 
As the reader allows a wider set of codes to be selected, the following formats are 
defined to offer the user all the reading possibilities of the Datalogic product. 
 
 

Conversion to Code 39 Format 

Data from any code selected may be transmitted. Each code is transmitted to the 
Host as Code 39. Any character not included in the standard Code 39 set will be 
replaced with a “Space” (20 Hex). 
 
 

IBM  Standard Format (default) 

Only codes belonging to the above mentioned set may be transmitted. Each code 
transmitted to the Host is recognized by the identifier requested by the protocol. If 
the selected code does not belong to this set, it wiII not be transmitted. 
 
 

MIXED IBM  St Code 39  Format 

Data from any code selected may be transmitted. For codes belonging to the 
above-mentioned set, the “IBM Standard Format” is applied. The “Code 39’ Format 
applies to codes not belonging to this set. 
 
 

USING GRYPHON

 D110 READERS 

 

 

 
 
Gryphon

 guns automatically scan barcodes 

at a distance

. Simply aim and pull 

the trigger. Code scanning is performed along the center of the light bar emitted
from the reading window. This bar must cover the entire code. 
Successful scanning is obtained by tilting the scanner with respect to the barcode 
to avoid direct reflections, which impair the reading performance, see the figure
above. 
Successful reading is obtained by an audible tone plus a
good-read green spot. 
 

 
 

 