background image

GRYPHON™ BT 

 

11 

 

UK/US 

SERIAL CONFIGURATION OPTIONS 

 
In addition to the battery charge function C-GRYPHON can be connected to a 
PC by means of an RS232 interface to send new configuration strings from the 
PC to the reader (i.e. using DL Sm@rtSet™), to upgrade application software 
onto the Gryphon™ BT reader or optionally when performing the copy 
configuration procedure (see the Gryphon™ BT Reference Manual). 

 

 

Host interface connector 

 
To proceed with these operations, connect an RS232 cable between  
C-GRYPHON and the PC. Connect the power supply to C-GRYPHON. Place 
the Gryphon™ BT reader onto the charger. 
 
 

Power Supply 

RS232 Interface to PC 

Summary of Contents for GRYPHON BT100

Page 1: ...1 GRYPHON BT Quick Reference ...

Page 2: ...ically scan barcodes at a distance Simply aim the reader and pull the trigger Code scanning is performed along the center of the light bar emitted from the reading window This bar must cover the entire code READING ANGLE Successful scanning is performed by tilting the reader with respect to the barcode to avoid direct reflections which impair the reading performance see the figure below Successful...

Page 3: ...Blinking C GRYPHON receives commands from the Host Red On the battery charge is in progress Green On the battery is completely charged D I S C H A R G E After many recharging cycles NiMh and NiCd batteries may tend to lose their operating autonomy This condition can be overcome by positioning the Gryphon BT onto the C GRYPHON charger and pressing the battery reconditioning button A discharge cycle...

Page 4: ...e handle and screw it back into place See the following figures CAUTION Dispose of the batteries as required by the relevant laws in force Powering the C GRYPHON CAUTION Connections should always be made with power off Apply power to C GRYPHON by connecting a power supply unit to the connector on the base of the battery charger C GRYPHON is ready to charge Gryphon BT Series readers with NiMh or Ni...

Page 5: ...or PC 2 Power up the Gryphon BT reader within radio range 10 meters Any modifications to the radio configuration should be made at this time before the radio connection takes place 3 From the remote Bluetooth Master device execute the Discovery procedure according to the procedure given in the documentation of the Bluetooth Master device to recognize the Gryphon BT reader s within radio range 4 Ch...

Page 6: ...SSION The transmission of data can be transparent no ACK NACK protocol when each character is read and immediately sent to the Host default value Otherwise data transmission can be with flow control with ACK NACK protocol when after each reading Gryphon BT waits for an acknowledge that the remote Host received the data before reading and sending the following code NOTE RTS CTS handshaking should b...

Page 7: ... the two procedures below and reading the codes in the given sequence GRYPHON BT AS SLAVE Restore Gryphon BT default 1 i Pk i Pk i Pk Set Gryphon BT as Slave 2 i 25 k i 25 k i 25 k YOUR READER IS NOW READY TO BE DISCOVERED CONNECTED VIA RADIO BY A BLUETOOTH MASTER DEVICE AND READ BARCODES ...

Page 8: ... Gryphon BT as Master 2 i 25 Dk i 25 Dk i 25 Dk Enter configuration 3 i k i k i k Set Remote Bluetooth Device Address slave 4 i242k i242k i242k 12 hexadecimal characters for the remote Bluetooth device address Exit and Save configuration 5 i k i k i k Request Radio Connection with Slave 6 i 2 gk i 2 gk i 2 gk YOUR READER IS NOW CONFIGURED TO READ BARCODES USING THE DEFAULT VALUES ...

Page 9: ...n medium beeper control for radio response ON DECODING PARAMETERS ink spread enabled overflow control enabled interdigit control enabled Puzzle Solver disabled decoding safety one read CODE SELECTION enabled codes BT200 Code PDF417 EAN 8 EAN 13 UPC A UPC E without ADD ON check digit transmitted no conversions Interleaved 2 5 check digit control and transmission variable length code 4 99 characters...

Page 10: ...DIO PARAMETERS radio protocol timeout 3 seconds transmission retry none no ACK NACK protocol nor frame packing power off timeout 4 hours user friendly name Gryphon BTx00 beeper control for radio response good decode and good reception Bluetooth role Slave destination address 000000000000 auto connection enabled auto reconnection enabled ...

Page 11: ...eader i e using DL Sm rtSet to upgrade application software onto the Gryphon BT reader or optionally when performing the copy configuration procedure see the Gryphon BT Reference Manual Host interface connector To proceed with these operations connect an RS232 cable between C GRYPHON and the PC Connect the power supply to C GRYPHON Place the Gryphon BT reader onto the charger Power Supply RS232 In...

Page 12: ... 076 mm 3 mils PCS minimum 15 Datalogic Test Chart Radio Features Bluetooth version Bluetooth 1 1 Profiles supported Serial Port Profile Working frequency 2 4000 to 2 4835 GHz Maximum output power 2 5 mW class 2 Range in open air 10 m Environmental Features Working Temperature 0 to 40 C 32 to 104 F Storage Temperature without battery 20 to 70 C 4 to 158 F Humidity 90 non condensing Drop resistance...

Page 13: ...to 40 C 32 to 104 F Storage temperature 20 to 70 C 4 to 158 F Humidity 90 non condensing Protection class IP30 Communications Interface RS232 Baud Rate 9600 Data Bits 8 Stop Bit 1 Parity None Mechanical Features Weight about 250 g 8 81 oz Dimensions 208 x 107 x 55 5 mm 8 1 x 4 2 x 2 18 in Material ABS Having a switching regulator inside the C GRYPHON draws the same power regardless of the supply v...

Page 14: ... able to initialize radio communication with the remote Bluetooth device server SOLUTION Put the reader near the remote Bluetooth device and try to initialize the radio communication again Make sure that the remote Bluetooth device is powered the protocol version is compatible with Gryphon BT s protocol the remote Bluetooth device is not yet connected to another BT device with the same SPP Repeat ...

Page 15: ...ommunicate with it SOLUTION Make sure that the remote Bluetooth device has not any communication protection i e a password the protocol version is compatible with Gryphon BT s PROBLEM It seems that the Gryphon BT radio communication range is less than 10 m SOLUTION Check that there are no obstacles to radio transmission between the devices ...

Page 16: ...ded that the product is operated under normal and proper conditions Datalogic has the faculty to repair or replace the product these provisions do not prolong the original warranty term The warranty does not apply to any product that has been subject to misuse accidental damage unauthorized repair or tampering PATENTS This product is licensed under one or more of the following U S patents 4 282 42...

Page 17: ... radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is ...

Page 18: ... mils CODE 39 0 076 mm 3 mils 0 13 mm 5 mils GRYPHON BT200 PDF 0 5 10 15 20 25 30 35 10 5 0 5 10 M200 PDF Reading Zones 10 skew angle cm CODE39 0 076 mm 3 mils CODE39 0 13 mm 5 mils EAN13 M 1 0 33 mm 13 mils CODE39 0 50 mm 20 mils 0 13 mm 5 mils 0 2 4 6 8 10 12 14 16 8 6 4 2 0 2 4 6 8 cm M200 PDF PDF417 codes Reading Zones 10 skew angle PDF417 Aspect Ratio 3 1 0 25 mm 10mils 0 17 mm 6 6mils 0 38 m...

Page 19: ...C TABLE i k i k i k i k i k i k 0 1 i k i k i k i k i k i k 2 3 i k i k i k i k i k i k 4 5 i k i k i k i k i k i k 6 7 i k i k i k i k i k i k 8 9 i k i k i k i k i k i k A B i k i k i k i k i k i k C D i k i k i k i k i k i k E F ...

Page 20: ...ion is based upon compliance of the products to the following standards Cette déclaration repose sur la conformité des produits aux normes suivantes Diese Erklärung basiert darauf daß das Produkt den folgenden Normen entspricht Esta declaración se basa en el cumplimiento de los productos con las siguientes normas EN 60950 1 December 2001 INFORMATION TECHNOLOGY EQUIPMENT SAFETY PART 1 GENERAL REQUI...

Reviews: