background image

 

 

 

 

DS6300 ETHERNET

 

14  

 

 

26-pin D-Sub Connector Pinout 

Pin Name 

Function 

Shield 

Internally connected by capacitor to chassis 

20 

RXAUX 

Receive data of auxiliary RS232 (referred to GND) 

21 

TXAUX 

Transmit data of auxiliary RS232 (referred to GND) 

OUT 1+ 

Configurable digital output 1 – positive pin 

22 OUT 

1-  Configurable 

digital output 1 – negative pin 

11 OUT 

2+  Configurable 

digital output 2 – positive pin 

12 OUT 

2-  Configurable 

digital output 2 – negative pin 

16 OUT 

3A  Configurable 

digital 

output 3 – polarity insensitive 

17 OUT 

3B  Configurable 

digital 

output 3 – polarity insensitive 

18 EXT_TRIG 

A External 

trigger (polarity insensitive) 

19 EXT_TRIG 

B External 

trigger (polarity insensitive) 

IN2A 

Input signal 2 (polarity insensitive) 

10 

IN2B 

Input signal 2 (polarity insensitive) 

14 

IN3A 

Input signal 3 (polarity insensitive) 

15 

IN4A 

Input signal 4 (polarity insensitive) 

24 

IN_REF 

Common reference of IN3 and IN4 (polarity insensitive) 

9, 13 

VS 

Supply voltage – positive pin 

23, 25, 26  GND 

Supply voltage – negative pin 

 

10

19

1

18

9

26

 

26-pin male D-sub Connector 

Pin 

RS232 

RS485 Full-Duplex 

RS485 Half-Duplex

 

20 mA C.L. 

(INT-30 with C-BOX 100 only)

2 TX 

TX485+  

3 RX 

RX485+ 

 

4 RTS 

TX485-  RTX485- 

5 CTS 

RX485- 

 

7 GND_ISO  GND_ISO  GND_ISO 

see INT-30 instructions

 

For 20 mA C.L. connections, GND is the same of the scanner power supply. 

 
 

9-pin Lonworks Connector Pinout 

Pin Name 

Function 

1 Shield 

Cable 

shield 

VS 

Supply voltage – positive pin 

GND 

Supply voltage – negative pin 

VS_I/O 

Supply voltage of I/O circuit 

3 Ref_I/O 

Reference voltage of I/O circuit 

4 SYS_ENC_I/O 

System 

signal 

5 SYS_I/O 

System 

signal 

LON A 

Lonworks line (polarity insensitive) 

LON B 

Lonworks line (polarity insensitive) 

 

5

 

1

 

9

 

6

 

 

9-pin female Local Lonworks Connector 

 
 

RJ45 Modular Connector 

 

DS6300 

HUB / SWITCH 

RX+

TX- 

TX+ 

RX- 

n. c. 

n. c. 

n. c. 

n. c. 

n. c. = not connected 

 

 

 

RJ45 Modular Connector 

Summary of Contents for DS6300

Page 1: ...DS6300 INSTALLATION QUICK REFERENCE...

Page 2: ...DS6300 100 012 ETHERNET MODELS 12 DS6300 100 015 DEVICENET MODELS 17 DS6300 105 0XX OSCILLATING MIRROR MODELS 22 COMMON FEATURES 24 NOTE For further details on product installation see the complete Re...

Page 3: ...15 W typical 20 W Max including startup current Main isolated Baud Rate Safety Class Class 2 EN 60825 1 Class II CDRH RS232 RS485 full duplex Laser Control Security system to turn laser off in case of...

Page 4: ...1271 CAB 6101 Cable master slave 1 m 93A051220 CAB 6102 Cable master slave 2 m 93A051230 CAB 6105 Cable master slave 5 m 93A051240 CAB 6112 Cable master slave no power 2 m 93A051224 CAB 6115 Cable mas...

Page 5: ...rence of IN3 and IN4 polarity insensitive 9 13 VS Supply voltage positive pin 23 25 GND Supply voltage negative pin 14 1 25 13 25 pin male D sub Connector Pin RS232 RS485 Full Duplex RS485 Half Duplex...

Page 6: ...lti slave network P S Presence Sensor connected to External Trigger input Pass Through Layout E N T E N T P S Presence Sensor connected to External Trigger input 1 2 Main Serial Interface Auxiliary Se...

Page 7: ...Network Single P S Single P S with 2 Readers P S Presence Sensor connected to External Trigger input Master CAB 600X CAB 610X Slave 1 Local Host C BOX 100 PG6000 BTK 6000 BTK 6000 P S DS4600A C BOX 1...

Page 8: ...2 Readers and Single Power Unit P S Presence Sensor connected to External Trigger input Master CAB 600X CAB 610X Slave 1 Slave 2 Local Host C BOX 100 PG6000 CAB 610X BTK 6000 BTK 6000 P S CAB 611X Sl...

Page 9: ...pical 20 W Max including startup current Main isolated Baud Rate Safety Class Class 2 EN 60825 1 Class II CDRH RS232 RS485 full duplex Laser Control Security system to turn laser off in case of motor...

Page 10: ...21 CAB 6012 Cable to C BOX100 2 m 93A051222 CAB 6015 Cable to C BOX100 5 m 93A051223 C BOX 100 Passive connection box 93ACC1510 INT 30 20 mA C L interface board for C BOX 100 93A151022 GFC 60 90 mirro...

Page 11: ...age positive pin 23 25 26 GND Supply voltage negative pin 10 19 1 18 9 26 26 pin male D sub Connector Pin RS232 RS485 Full Duplex RS485 Half Duplex 20 mA C L INT 30 with C BOX 100 only 2 TX TX485 RTX4...

Page 12: ...2 DS6300 readers Please contact Datalogic USS Technical Support if your application requires a multi slave network P S Presence Sensor connected to External Trigger input Remote Host DS6300 C BOX 100...

Page 13: ...ation requires a multi slave network P S Presence Sensor connected to External Trigger input The Slave scanners are Master Slave models which allow Lonworks network propagation Remote Host DS6300 Mast...

Page 14: ...ypical 20 W Max including startup current Main isolated Baud Rate Safety Class Class 2 EN 60825 1 Class II CDRH RS232 Laser Control Security system to turn laser RS485 full duplex off in case of motor...

Page 15: ...221 CAB 6012 Cable to C BOX100 2 m 93A051222 CAB 6015 Cable to C BOX100 5 m 93A051223 C BOX 100 Passive connection box 93ACC1510 INT 30 20 mA C L interface board for C BOX 100 93A151022 GFC 60 90 mirr...

Page 16: ...4 polarity insensitive 24 IN_REF Common reference of IN3 and IN4 polarity insensitive 9 13 VS Supply voltage positive pin 23 25 26 GND Supply voltage negative pin 10 19 1 18 9 26 26 pin male D sub Con...

Page 17: ...2 DS6300 readers Please contact Datalogic USS Technical Support if your application requires a multi slave network P S Presence Sensor connected to External Trigger input Remote Host DS6300 C BOX 100...

Page 18: ...ation requires a multi slave network P S Presence Sensor connected to External Trigger input The Slave scanners are Master Slave models which allow Lonworks network propagation Remote Host DS6300 Mast...

Page 19: ...0 W Max including startup current Safety Class Class 2 EN 60825 1 Class II CDRH Main isolated Baud Rate Laser Control Security system to turn laser RS232 off in case of motor slow down RS485 full dupl...

Page 20: ...A051221 CAB 6012 Cable to C BOX100 2 m 93A051222 CAB 6015 Cable to C BOX100 5 m 93A051223 C BOX 100 Passive connection box 93ACC1510 INT 30 20 mA C L interface board for C BOX 100 93A151022 GFC 60 90...

Page 21: ...ly voltage negative pin 10 19 1 18 9 26 26 pin male D sub Connector Pin RS232 RS485 Full Duplex RS485 Half Duplex 20 mA C L INT 30 with C BOX 100 only 2 TX TX485 RTX485 3 RX RX485 4 RTS TX485 RTX485 5...

Page 22: ...2 DS6300 readers Please contact Datalogic USS Technical Support if your application requires a multi slave network P S Presence Sensor connected to External Trigger input Remote Host DS6300 C BOX 100...

Page 23: ...cation requires a multi slave network P S Presence Sensor connected to External Trigger input The Slave scanners are Master Slave models which allow Lonworks network propagation Remote Host DS6300 Mas...

Page 24: ...imits of the oscillation by defining the top and bottom line limit angles When the oscillating mirror is programmed to read barcode labels at very small angles position the reader to assure at least 1...

Page 25: ...ssary the number of scans on the reading surface is increased Oscillating angles are selected in software where the minimum and maximum angles correspond to 2 5 and 37 5 The scanner can be tilted in o...

Page 26: ...sitive 30 IN 2B polarity insensitive 31 33 IN 3A polarity insensitive 32 34 IN 4A polarity insensitive 36 IN 3B IN 4B Reference polarity insensitive Outputs 21 OUT 1 22 OUT 1 23 OUT 2 24 OUT 2 25 OUT...

Page 27: ...ead 6 completely tighten the four fixing screws Step A Head Feature The following diagrams give the overall dimensions of the reader standard model oscillating mirror model and mounting bracket They m...

Page 28: ...ally 0 for the best scanner orientation 45 Skew Installation The DS6300 scanner is mounted on the ST 210 90 mounting bracket By adjusting the mounting bracket guides reach 45 for the Skew angle S in t...

Page 29: ...optic Head 2 Press and hold both the up arrow and down arrow key for about 2 seconds to enter the Main menu 3 Use the up arrow or down arrow key to select Test Mode item then press the ENT enter key...

Page 30: ...focus position and the reading percentage on the terminal tool provided by the Genius configuration program see Genius Help On Line for details Reading Diagrams In the following reading diagrams 0 0 i...

Page 31: ...10 6 4 2 60 65 22 20 24 26 Focus Position 0 30 12 30 12 70 75 80 85 30 28 32 34 Focus Position 40 Focus Position 60 DS6300 100 0XX Resolution 0 50 mm 20 mils CONDITIONS Code Interleaved 2 5 or Code 3...

Page 32: ...10 0 cm 5 5 10 15 20 25 8 10 8 10 6 4 2 55 60 20 18 22 24 Focus Position 40 Focus Position 0 DS6300 105 0XX Oscillating Mirror Resolution 0 30 mm 12 mils CONDITIONS Code Interleaved 2 5 or Code 39 PC...

Page 33: ...cus Position 60 8 4 0 12 in 50 40 30 20 0 cm 10 10 20 30 40 50 16 20 16 20 12 8 4 60 24 60 24 Focus Position 100 0 8 20 in 12 16 24 28 0 20 30 40 50 60 70 80 90 cm 100 36 32 40 44 48 52 56 110 120 130...

Page 34: ...9 Safety Precautions Figure A Laser Safety Label 1 Identification Label 2 Figure B Warning and Device Class Label 1 Figure C Laser Safety Label 1 The scanner is classified as a Class 2 laser product a...

Page 35: ...and Device Class Label Device Identification Label The laser diode used in this device is classified as a Class 3B laser product according to EN 60825 1 regulations and as a Class IIIb laser product...

Page 36: ...es relative la compatibilit lectromagn tique et la s curit des produits ber die Ann herung der Gesetze der Mitgliedsstaaten in bezug auf elektromagnetische Vertr glichkeit und Produktsicherheit entspr...

Reviews: