OM CONFIGURATION PARAMETERS
NOTE
The DS4800 OM scanner is configurable exclusively through the Genius™ utility program. The
DS4800 scanner must have software version 004 or later.
The following software configuration parameters are available through Genius™ and described below for
reference:
Oscillating Mode
This parameter defines the oscillating mode of the scanner mirror:
Selections:
Fixed
the oscillating mirror deflects the scan line at a fixed
Angle
(default 0°).
Continuous
the scan line is deflected according to the
Min-Max Angle
and
Frequency
settings.
Angle (degrees)
This parameter is available only when working in
Fixed
oscillating mode.
It defines the angle in degrees with respect to the angle perpendicular to the scanner (0°).
Selections:
a value from
-5°
to
35°
:
Min Angle (degrees)
This parameter is available only when working in
Continuous
oscillating mode.
It defines the minimum angle for the deflection range with respect to the angle perpendicular to the scanner (0°).
Selections:
a value from
-5°
to
35°
:
Max Angle (degrees)
This parameter is available only when working in
Continuous
oscillating mode.
It defines the maximum angle for the deflection range with respect to the angle perpendicular to the scanner (0°).
Selections:
a value from
-5°
to
35°
:
Frequency (Hz)
This parameter is available only when working in
Continuous
oscillating mode.
It defines the oscillating frequency in Hertz:
Selections:
a value from
0.2
to
20.0
Hertz
NOTE
The maximum allowable frequency for the given oscillating amplitudes is:
30.5° to 40°
5 Hz
20.5° to 30°
7 Hz
10.5° to 20°
10 Hz
0.5 to 10°
20 Hz
Triggered
If checked, it allows assigning a trigger through which the oscillating mirror can be activated to work in a second
reading zone according to the defined parameters.