DS4300
DATALOGIC
2.18
- Installation
18/6/14
+
19/10/15
-
+ 5V
DS4300
USER INTERFACE
V
Signal
Ground
30 Vdc max.
Vext
Figure 2.22 - Input PNP command using external power
18/6/14
+
19/10/15
-
USER INTERFACE
DS4300
VS
9
25
GND
V
Signal
+ 5V
Figure 2.23 - Input PNP command using DS4300 power
The electrical features of the inputs are:
Maximum voltage = 30 Vdc
Maximum current = 25 mA.
An anti-disturbance hardware filter is implemented on the External Trigger
input (< 5 milliseconds delay).
An additional 15 ms (typical) delay can be implemented through a dedicated
software parameter (refer to WinHost Help On Line).