DS2 Ethernet
Instruction Manual
20
6.1.6. Functions
The configuration session in entered pressing the button
Configure
.
The access to the remote programming foresees the transmission of a particular command that
stops the scanning while the configuration session is active. The following message will be shown.
If the command is accepted, the button
Configure
changes and becomes
End
, and the buttons
Download
and
Upload
are enabled. Now the controls inside the property pages become active.
We distinguish five different sections in the
Remote Prog.
page
:
Transmission Enable:
the transmission can be controlled by means of
Software
or
Hardware
. If the
Software
option is enabled, the data will be transmitted according to the settings of the section
Setting Mode
. The
Hardware
option allows the flow of data to be activated/interrupted by means of
an external signal applied to the TEACH-IN input: 24VDC transmission ON, 0VDC transmission
OFF. In this case, the
Software
option must be disabled, otherwise the data will be transmitted no
matter the state of the TEACH-IN input. It is also possible to completely disable the serial
transmission with both options unchecked. It remains active only for the communication with the
host.
Default Conf.
: with the
Restore
button, the default configuration will be restored.
Data Packet:
used to set the type of transmission (binary or ASCII) of the data. A very simply
transmission mode can be enabled by means of the
Short Protocol
check box. In this way a single
will be transmitted containing a numerical measure.