DRAGON™
6
2
The two RS485 connectors are identical in every respect so that the point-to-point
cables can be chained together without limitations concerning the bus wiring.
Obviously cable length is to be kept to a minimum as with all bus systems.
2.6.2 Network
Cabling
The Multidrop line is made using RJ45 connectors and a cable having the following
specifications:
•
twisted pair AWG 24 wires
•
120
Ω
impedance
•
maximum network cable length 1200 meters
Pin Function
Multidrop
Cables
1 RS485
+
2 RS485
-
3 N.C.
4 VDC
–
5 VDC
–
6 N.C.
7 VDC
+
8 VDC
+
5
2
RJ45
5
2
RJ45
1
1
VDC-
RS485-
RS485+
Twisted Pair - RS485 bus
8
5
2
RJ45
8
5
2
RJ45
1
1
Twisted Pair - RS485 bus
Twisted Pair - Power supply
VDC+
VDC-
RS485
RS485
When wiring the multidrop cables, note the following:
Pin 8 (or 7) can be connected only if the power has to be propagated from a cradle to a
STARGATE™ base station or STAR-Box™ converter via the cable.
Pins 5 (or 4) should always be connected as reference ground.
To avoid excessive voltage drop, it is recommended to not propagate power between
OM-DRAGON™ cradles when used as battery chargers but to supply each cradle
Data
only
Data
and
Power
Supply
Pin 1