CBX500 INSTALLATION MANUAL
9
SYSTEM WIRING
The connection and wiring procedure for CBX500 is described as follows:
1) Open the CBX500 by unscrewing the four cover screws.
2) Verify that the CBX500 power switch is off (see Figure 3).
3) Unscrew the compression connectors and pass all the system cables through them into
the CBX500 housing.
4) To connect the power and input/output signals:
Prepare the individual wires of the system cables by stripping the insulation back
approximately 1 cm.
Using a device such as a screwdriver, push down on the lever directly next to the
clamp (see Figure 5).
Insert the wire into the clamp and release the lever.
The wire will now be held in the spring clamp.
5) Tighten the compression connector nuts so that the internal glands seal around the
cables.
Figure 5 - System Cable Connections
Flexible stranded wire should be used and must meet the following specifications.
All positions: 24 - 16 AWG 0.2 - 1.5 mm²
The CBX500 spring clamp connector pinouts are indicated in the Pinout table.