Linear Scanner Pinouts 

Pin Name 

1, 3, 5 

VS 

2, 4, 6 

GND 

7, 8 

EARTH GROUND 

*9, 13 

RS485 CABLE SHIELD 

20, 40 

RESERVED 

35 TX 

AUX 

37 RX 

AUX 

 

 

 

DS2100A 
DS2400A

 

DS4600A DS1100 

DS2200 

DS6XXX 
DX6XXX 

DS8100A 

21 

OUT1+ OUT1+ OUT1+ OUT1+ 

22 OUT 

REF 

OUT1- 

IO 

REF 

OUT1- 

23 

OUT2+ OUT2+ OUT2+ OUT2+ 

24 OUT 

REF 

OUT2- 

IO 

REF 

OUT2- 

25 NC 

RESERVED 

NC 

OUT 

3A 

26 NC 

RESERVED 

IN1- 

OUT 

3B 

27 

EXT TRIG+ 

EXT TRIG+ 

EXT TRIG+ 

EXT TRIG/PS 

28 

EXT TRIG- 

EXT TRIG- 

EXT TRIG- 

EXT TRIG/PS 

29 

NC IN1+ NC 

IN 

2/ENC 

30 

NC 

IN1- 

IO REF 

IN 2/ENC B 

31 

NC IN2+ NC IN 

3A 

32 NC 

IN2- 

NC 

IN 

4A 

33 RESERVED 

RESERVED RESERVED 

IN 

3A 

34 RESERVED 

RESERVED RESERVED 

IN 

4A 

36 

RTSA 

GND 

NC 

IN 3B/IN 4B 

38 CTSA 

SGND 

AUX 

NC 

GND 

39 

GND GND GND GND 

 

DS2100A DS2400A DS4600A DS6XXX DX6XXX DS8100A 

 

RS232 RS485FD 

RS485HD  20mA 

CL 

(with INT-30 only) 

*11, 15 

TX232 

TX485+ 

 

*12, 16 

RTS232 

TX485- 

RTX485- 

17 RX232 

RX485+ 

 

18 CTS232 

RX485- 

 

*10, 14, 19 

SGND MAIN  SGND MAIN  SGND MAIN 

see INT-30 

instructions 

 

DS1100 DS2200 

 

  

RS485HD 

 

*11, 15 

 

 

 

 

*12, 16 

 

 

RTX485- 

 

17  

 

RESERVED 

 

18  

 

RESERVED 

 

*10, 14, 19 

 

 

SGND MAIN 

 

 

*  The signals on pins 9, 10, 11 and 12 are repeated on pins 13, 14, 15 and 16 to facilitate 

network connections (i.e. Multiplexer connections using the RS485 half-duplex Interface). In 
this way the network bus can enter and exit the C-Box 100 from different spring clamps but be 
physically connected together. 

 

2D Reader/Camera Pinouts 

Pin Name 

1, 3, 5 

VS 

2, 4, 6 

GND 

7, 8 

EARTH GROUND 

20, 40 

RESERVED 

 

MATRIX-

2XXX

 

MATRIX-

1XXX 

DV9500 

*9, 13 

RS485 CABLE SHIELD 

RESERVED 

35 TX 

AUX 

RX2 232 

37 RX 

AUX 

TX2 232 

21 OUT1+ 

NC 

RESERVED 

22 OUT1- 

NC 

RESERVED 

23 OUT2+ 

NC 

GND3 

24 OUT2- 

NC 

 

25 OUT3+ 

OUT3+ 

TX3 

485- 

26 OUT3- 

OUT3-  TX3 

485+ 

27 

EXT TRIG A 

EXT TRIG A 

RX3 485- 

28 

EXT TRIG B 

EXT TRIG B 

RX3 485+ 

29 IN 

2A 

NC 

PS- 

30 IN 

2B 

NC 

PS+ 

31 NC 

NC 

OE+ 

32 NC 

NC 

OE- 

33 NC 

NC 

OE+ 

34 NC 

NC 

OE- 

36 NC 

NC  OUTPUT- 

38 GND 

GND 

GND2 

39 GND 

GND 

GND 

 

  These signals are not available by default but require DV9500 internal jumper settings. 

 

MATRIX-2XXX 

 

RS232 RS485FD 

RS485HD  20mA 

CL 

(with INT-30 only) 

*11, 15 

TX232 

TX485+ 

 

*12, 16 

RTS232 

TX485- 

RTX485- 

17 RX232 

RX485+ 

 

18 CTS232 

RX485- 

 

*10, 14, 19 

SGND MAIN  SGND MAIN  SGND MAIN 

see INT-30 

instructions 

 

MATRIX-1XXX 

 

  

RS485HD 

 

*11, 15 

 

 

 

 

*12, 16 

 

 

RTX485- 

 

17  

 

NC 

 

18  

 

NC 

 

*10, 14, 19 

 

 

SGND MAIN 

 

 

DV9500 

 

 

 

 

 

*11, 

15 

   INPUT- 

*12, 

16 

   

GND1 

17     

INPUT+ 

18     

RX1 232 

*10, 14, 19 

 

 

 

TX1 232 

  These signals are not available by default but require DV9500 internal jumper settings. 

 
 

SCANNER SELECTION 

A

DS1100 
DS2200 

Other Devices 

B

 

Figure 8 - Scanner Selection 

 
Switch S3 must be set to A only when a DS1100 or a DS2200 scanner 
(10-30 V version) is connected. For all the other devices switch S3 must 
be set to B. 
 
 

RS485 BUS TERMINATION 

ON 

S2 

OFF 

 

Figure 9 - Termination Resistance Switch 

 
Switch S2 enables or disables the insertion of the bus termination 
resistor for RS485 Half Duplex Multidrop applications. 
 

 

CAUTION 

In Multiplexer applications the termination resistor 
must be enabled ONLY on the last device of the 
chain, the farthest away from the Multiplexer 
(assuming the Multiplexer is the first device of the 
chain). On all the other devices this resistor MUST 
NOT be enabled (S2 = OFF). 

 
 

 

NOTE 

For all RS485 connections, in case of electrically noisy 
environments: C-BOX 100 should be connected to a 
good earth ground (pin 7 or 8), RS485 CABLE SHIELD 
should be connected to pin 7 or 8, the scanner chassis 
should be connected to EARTH GROUND through the 
jumper, see Figure 7. 

 
 
 
 
 
 
 
 

821000554 (Rev. E) 

OM4000 JUMPER SETTINGS 

 

J1

J2

 

Figure 10 - OM4000 Jumpers 

 
These jumpers allow connection to the EXT TRIG signals on separate 
spring clamp terminals for applications which use the OM4000 
Oscillating Mirror in Trigger Mode. 

When jumper J1 is inserted, pin 40 is connected to pin 27 (EXT TRIG+); 
jumper J2 inserted connects pin 20 to pin 28 (EXT TRIG-). 

When the jumpers are removed, pin 20 and pin 40 are disconnected. 
 
 

9-PIN SCANNER AUXILIARY SERIAL INTERFACE 

 
The scanner auxiliary serial interface available on the internal 9-pin 
connector can be used either for configuration or for data monitoring. 

The details of the connector pins are indicated in the following table: 

 

Figure 11 - 9-pin Male Connector 

 

9-pin Connector Pinout 

Pin Name Function 

1  

N.C. 

2 RXA 

Auxiliary 

RS232 

3 TXA 

Auxiliary 

RS232 

4  

N.C. 

5 GND 

Ground 

6  

N.C. 

7 RESERVED 

Device 

Dependent 

Signal 

8 RESERVED 

Device 

Dependent 

Signal 

9  

N.C. 

 

 

NOTE 

Pins 7 and 8 have different signals attributed to them 
depending on the device connected to C-BOX 100. It 
is recommended to use only pins 2, 3, and 5 for 
communications. 

 
 

 

CAUTION

Do not use the 9-pin connector when C-BOX 100 is 
connected to DV9500. 

 
 

TECHNICAL FEATURES 

 

ELECTRICAL FEATURES 

 

Supply Voltage 

10 to 30 Vdc* 

Power Consumption 

0.5 W + scanner power 

consumption 

(see related manual) 

Max Current Consumption 

(short circuit protection on 25-pin 
connector) 

2 to 2.5 A 

USER INTERFACE 

 

LED Indicators 

Power on LED (green) 

Power polarity error LED (red) 

 
*  for further details about minimum/maximum supply voltage refer to 

the manual of the connected scanner, since the minimum supply 
voltage required may be >10. 

 

PHYSICAL FEATURES 

 

Mechanical Dimensions 

161 x 114.5 x 40 mm 

(6.34 x 4.51 x 1.57 in.) 

Weight 

about 320 g. (11.29 oz.) 

ENVIRONMENTAL FEATURES   

Operating Temperature 

-10° to 50 

°

C (+14° to 122 °F) 

Storage Temperature 

-20° to 70 

°

C (-4° to 158 °F) 

Humidity max. 

90% non condensing 

Vibration Resistance 

14 mm @ 2 to 10 Hz 

EN 60068-2-6 
2 hours on each axis 

1.5 mm @ 13 to 55 Hz 

2 g @ 70 to 200 Hz 

Shock Resistance 

30 g; 11 ms; 

EN 60068-2-27 

3 shocks on each axis 

Protection Class 

IP64 

(when correctly connected to the scanner) 

The features given are typical at a 25 

°

C ambient temperature (if not otherwise 

indicated). 

 

WEEE COMPLIANCE 

 

Information for the user in accordance with the European Commission 
Directive 2002/96/EC 

 
At the end of its useful life, the product marked with the crossed out wheeled 
wastebin must be disposed of separately from urban waste. 
 
Disposing of the product according to this Directive: 

• 

avoids potentially negative consequences to the environment and human health which 
otherwise could be caused by incorrect disposal 

• 

enables the recovery of materials to obtain a significant savings of energy and resources. 

 
For more detailed information about disposal, contact the supplier that provided you with the 
product in question or consult the dedicated section at the website 
www.automation.datalogic.com. 

 

CE COMPLIANCE 

 

Warning:

 This is a Class A product. In a domestic environment this product may cause radio 

interference in which case the user may be required to take adequate measures. 

 

 

DECLARATION OF CONFORMITY

 

07

Datalogic Automation S.r.l. 

Via S. Vitalino 13 

40012 - Lippo di Calderara 

Bologna - Italy 

dichiara che 
declares that the 
déclare que le 
bescheinigt, daß das Gerät 
declare que el 

C-BOX 100, passive connection box 

e tutti i suoi modelli

 

 

and all its models 

 

et tous ses modèles 

 

und seine modelle 

 

y todos sus modelos 

sono conformi alle Direttive del Consiglio Europeo sottoelencate: 
are in conformity with the requirements of the European Council Directives listed below: 
sont conformes aux spécifications des Directives de l'Union Européenne ci-dessous: 
der nachstehend angeführten Direktiven des Europäischen Rats: 
cumple con los requisitos de las Directivas del Consejo Europeo, según la lista siguiente: 

89/336/EEC EMC Directive

 e 

92/31/EEC, 93/68/EEC 

emendamenti successivi

 

 and further 

amendments 

 

et 

ses successifs amendements 

 und späteren 

Abänderungen 

 y succesivas 

enmiendas 

Basate sulle legislazioni degli Stati membri in relazione alla compatibilità elettromagnetica ed 
alla sicurezza dei prodotti. 
On the approximation of the laws of Member States relating to electromagnetic compatibility and 
product safety. 
Basée sur la législation des Etats membres relative à la compatibilité électromagnétique et à la 
sécurité des produits. 
Über die Annäherung der Gesetze der Mitgliedsstaaten in bezug auf elektromagnetische 
Verträglichkeit und Produktsicherheit entsprechen. 
Basado en la aproximación de las leyes de los Países Miembros respecto a la compatibilidad 
electromagnética y las Medidas de seguridad relativas al producto. 
 
Questa dichiarazione è basata sulla conformità dei prodotti alle norme seguenti: 
This declaration is based upon compliance of the products to the following standards: 
Cette déclaration repose sur la conformité des produits aux normes suivantes: 
Diese Erklärung basiert darauf, daß das Produkt den folgenden Normen entspricht: 
Esta declaración se basa en el cumplimiento de los productos con las siguientes normas: 

EN 55022, August 1994

Amendment A1 (Class A ITE), October 2000: 

L

IMITS AND METHODS OF MEASUREMENTS OF RADIO 

DISTURBANCE CHARACTERISTICS OF INFORMATION 
TECHNOLOGY EQUIPMENT

 

 

 

EN 61000-6-2, October 2001

:

 

E

LECTROMAGNETIC COMPATIBILITY 

(EMC) 

P

ART 

6-2: G

ENERIC 

S

TANDARDS 

– I

MMUNITY FOR 

INDUSTRIAL ENVIRONMENTS

 

 

Lippo di Calderara, April 2nd, 2007 

Lorenzo Girotti 

Product & Process Quality Manager 

 

 

Reviews: