LASER MARKER STATES
USER MANUAL
43
LASER MARKER STATES
Normal Operation States
This state occurs since the laser marker is
switched on until Laser Engine has been loaded
and no errors occurred
Blinking
In this state the laser marker cannot emit IR lasers
radiation and Aiming and Focus beam cannot be
activated
Steady
In this state Aiming and Focus beam can be acti-
vated while the laser marker cannot emit IR laser
radiation
Steady
In this state the laser marker is able to emit IR
laser radiation
Steady
Error States
This state occurs if the laser marker detects an
error that prevents normal operation
Blinking
This error occurs if the INTERLOCK function is ON. To reset the error,
set INTERLOCK function to OFF and repeat the turning on sequence
This error occurs if the CONNECTOR_PRESENCE signal (pin X1.10
Command Box connector) is LOW or not connected. To reset the
error, set CONNECTOR_PRESENCE signal to HIGH value and repeat
the turning on sequence
This error occurs if the temperature inside the control rack is out of
the operating temperature range. To reset the error, a Laser marker
restart is required
This error occurs if the temperature inside the scan head is out of the
operating temperature range. To reset the error, a Laser marker
restart is required
This alarm occurs if the cable between control rack and scan head is
not connected. To reset the error, a Laser marker restart is required
STATE
DESCRIPTION
STATUS LED
SYSTEM BOOTING UP
WAIT FOR START
STANDBY SHUTTER
CLOSED
READY
STATE
DESCRIPTION
STATUS LED
ERROR
SYSTEM ERROR
DESCRIPTION
INTERLOCK ERROR
CBOX ERROR
RACK TEMPERATURE
ERROR
SCANHEAD
TEMPERATURE ERROR
SCANHEAD
CONNECTION ERROR