TECHNICAL SPECIFICATIONS
30
AREX™ 401
X3 - SLO Electric Diagram
VCC
INTERLOCK_A
VCC
LASER_STOP_A
/LASER_STOP_A
GND
INTERLOCK_B
LASER_STOP_B
/LASER_STOP_B
GND
SAFETY_FDBK-
SAFE
LASER MARKER
LASER MARKER
Figure 20: X3 - SLO connector, electric diagram
Input
Optocoupler
24 V DC
15 mA @ 24 V DC
≥ 1ms (debounce)
MIN
TYP
MAX
0.0 V DC
0.0 V DC
2.0 V DC
20.0 V DC
24.0 V DC
28.0 V DC
Table 2: Input specification
Output
Opto Relay
7 to 36VDC (24V nominal)
150 mA
8 Ω
≤
1 μA
Table 3: Output specification
TECHNICAL CHARACTERISTICS
Type
Vtyp
Imax
Pulse Width
INPUT Logic LOW
INPUT Logic HIGH
TECHNICAL CHARACTERISTICS
Type
Supply voltage
Imax
ON Resistance Max.
Leakage current