Figure 2 - Inserting the scanner in the Heated Holder

OPERATION

1. If the Heated Holder is connected to the ignition switch, turning the ignition switch on or off will control the heated holder. An LED 

illuminated from the inside of the holder indicates the power is on.

2. Place the scanner into the holder (see Figure 2). Push the scanner through the front brushes as far as it will go. The brushes should 

return to their original position.

WARNING: Do not put your fingers or hands inside the unit while it is on. Surfaces inside the unit are hot and may cause

burns. Do not use the Heated Holder as a handle; it is not intended to support human weight.

Heated
Holder

Scanner

Front
Brushes

European Declaration of Conformity

Hereby, Datalogic USA, Inc. declares that the full text of the Euro

-

pean Declaration of Conformity is available at: www.datalogic.com.
Select the Support & Service > Downloads > Product Certifications 

link where you can search for your specific product certification.

UKCA Declaration of Conformity

Hereby, Datalogic USA, Inc. declares that the full text of the UKCA 

Declaration of Conformity is available at: www.datalogic.com.
Select the Support &Service >Downloads > Product Certifications 

link where you can search for your specific product certification.

CHINA ROHS TABLE

SPECIFICATIONS

Physical

Dimensions

7.7 in. (19.6 cm) L

4.8 in. (12.2 cm) W

3.9 in. (9.9 cm) H

Environmental

Temperature

Internal  operating:  Operating  Solid  State  Control  at  95º-
105ºF (35º-40ºC)

Ambient operating: 22º to 104ºF (-30º to 40ºC)

Storage: -40º to 158ºF (-40º to 70ºC)

Humidity (Ambient)

: 5% to 95% (non-conducting)

Vibration

: MIL-STD-810E. Method 514.4, Procedure 1

Approvals

CE, TUV

Electrical

Power Cable

10 ft. (3.05 m) L (unterminated)

18/2 Conductor cable

Red wire: + positive lead

Black wire: - negative lead

Model Number

Input Voltage

Power Output (Nom.)

11-0139

24 VDC

75W

11-0138

36 VDC

75W

11-0140

48 VDC

75W