Electrical  equipment  should  be  installed  only  by  qualified  specialist.  No  responsibility  is 
assured  by  the  manufacturer  or  any  of  its  subsidiaries  for  any  consequences  resulting  from 
the non-compliance to these instructions. 

 

Check  the  unit  for  cracks  and  damages  due  to  transportation.  Do  not  install  damaged 
equipment. 

 

Do not open the unit. There are no serviceable parts inside. 

 

 Fuses must be connected to the power supply and phase voltage inputs, in close proximity of 
the unit. 

 

Fuses must be of fast type with a maximum rating of 6A. 

 

Disconnect all power before working on equipment. 

 

When the unit is connected to the network do not touch terminals. 

 

Any  electrical  parameter  applied  to  the  device  must  be  in  the  range  specified  in  the  user 
manual. Although the unit is designed with a wide safety margin, over-range parameters may 
reduce lifetime, alter operational precision or even damage the unit. 

 

Do not try to clean the device with solvent or the like. Only clean with a dump cloth. 

 

Verify correct terminal connections before applying power. 

 

 
 
 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

SAFETY NOTICE 

Failure to follow below instructions  

will result in death or serious injury

 

 

Summary of Contents for DKG-175

Page 1: ...and generator power availability as well as contactor positions Moreover mains phase voltages and frequency can be seen on front panel Mains voltage and frequency high and low limits mains waiting tim...

Page 2: ...in close proximity of the unit Fuses must be of fast type with a maximum rating of 6A Disconnect all power before working on equipment When the unit is connected to the network do not touch terminals...

Page 3: ...ALLATION INSTRUCTIONS 1 1 Front Panel 1 2 Electrical Connections 2 LED INDICATORS 3 PUSHBUTTON FUNCTIONS 4 OPERATION OF THE UNIT 4 1 Test Mode 5 PROGRAMMING 6 DECLARATION OF CONFORMITY 7 TECHNICAL SPE...

Page 4: ...in any case Below conditions may damage the device Incorrect connections Incorrect power supply voltage Voltage at measuring terminals beyond specified range Current at measuring terminals beyond spec...

Page 5: ...DKG 175 User Manual V 1 24 07 2017 5 1 1 Front Panel...

Page 6: ...es must be connected to the power supply and phase voltage inputs in close proximity of the unit Fuses must be of fast type with a maximum rating of 6A Use cables of appropriate temperature range Use...

Page 7: ...med limits Phase order is wrong if ALARM led is blinking Operation Mode Displays name of the measured value Programming Mode Click menu button to display current value of the parameter Click menu butt...

Page 8: ...actor timer GCB terminal is supplied with voltage G When mains voltages and frequency are inside the limits RST led turns on ALARM led turns off After the expiration of mains waiting timer GCB termina...

Page 9: ...parameter P2 to energise mains contactor P3 Mains frequency low limit Mains frequency must be higher than program parameter P3 to energise mains contactor P4 Mains frequency high limit Mains frequenc...

Page 10: ...European requirements for safety health environmental and customer protection Alternator voltage 170 300 V AC Phase Neutral Mains voltage 170 300 V AC configurable Phase Neutral Mains frequency 30 70...

Page 11: ...DKG 175 User Manual V 1 24 07 2017 11 DATAKOM Electronics Ltd Tel 90 216 466 84 60 Fax 90 216 364 65 65 e mail datakom datakom com tr http www datakom com tr 8 CONNECTION DIAGRAM...

Reviews: