DKG-175 AUTOMATIC 

TRANSFER SWITCH 

(WITHOUT DC SUPPLY) 

 

 

 

 

Datakom  DKG-175  is  a  DIN  Rail  mounted  ATS 
controller  not  requiring  DC  supply.  Thanks  to  this 
feature,  it  is  not  required  to  carry  the  DC  supply  from 
the  battery  to  the  transfer  panels,  providing  ease  of 
installation. 

The  unit  monitors  3-phase  mains  voltages,  sends 
remote  start  command  to  the  generating  set  and 
performs  changeover  of  both  generator  and  mains 
contactors. 

The  front  panel  leds  provide  information  about  mains 
and  generator  power  availability  as  well  as  contactor 
positions.  Moreover,  mains  phase  voltages  and 
frequency can be seen on front panel. 

Mains  voltage  and  frequency  high  and  low  limits, 
mains  waiting  timer,  mains  fail  timer,  generator  start 
delay,  cooldown  timer  and  mains  contactor  timer  are 
front  panel  programmable.  Generator  contactor  timer 
is adjustable between 1 and 40 seconds through front 
panel knob.  

 

DIN Rail mounted 

No DC supply required 

Mains phase order check 

Adjustable MCB and GCB delays 

Programmable mains frequency and voltage high 
and low limits 

Programmable delay timers 

10A/250VAC MCB and GCB outputs 

10A/28VDC remote start output 

Isolated mains and genset inputs 

Test mode

 

 

 

 

 

 

   

                   

                 

 

                                                                           

 

FEATURES 

DESCRIPTION 

Summary of Contents for DKG-175

Page 1: ...and generator power availability as well as contactor positions Moreover mains phase voltages and frequency can be seen on front panel Mains voltage and frequency high and low limits mains waiting tim...

Page 2: ...in close proximity of the unit Fuses must be of fast type with a maximum rating of 6A Disconnect all power before working on equipment When the unit is connected to the network do not touch terminals...

Page 3: ...ALLATION INSTRUCTIONS 1 1 Front Panel 1 2 Electrical Connections 2 LED INDICATORS 3 PUSHBUTTON FUNCTIONS 4 OPERATION OF THE UNIT 4 1 Test Mode 5 PROGRAMMING 6 DECLARATION OF CONFORMITY 7 TECHNICAL SPE...

Page 4: ...in any case Below conditions may damage the device Incorrect connections Incorrect power supply voltage Voltage at measuring terminals beyond specified range Current at measuring terminals beyond spec...

Page 5: ...DKG 175 User Manual V 1 24 07 2017 5 1 1 Front Panel...

Page 6: ...es must be connected to the power supply and phase voltage inputs in close proximity of the unit Fuses must be of fast type with a maximum rating of 6A Use cables of appropriate temperature range Use...

Page 7: ...med limits Phase order is wrong if ALARM led is blinking Operation Mode Displays name of the measured value Programming Mode Click menu button to display current value of the parameter Click menu butt...

Page 8: ...actor timer GCB terminal is supplied with voltage G When mains voltages and frequency are inside the limits RST led turns on ALARM led turns off After the expiration of mains waiting timer GCB termina...

Page 9: ...parameter P2 to energise mains contactor P3 Mains frequency low limit Mains frequency must be higher than program parameter P3 to energise mains contactor P4 Mains frequency high limit Mains frequenc...

Page 10: ...European requirements for safety health environmental and customer protection Alternator voltage 170 300 V AC Phase Neutral Mains voltage 170 300 V AC configurable Phase Neutral Mains frequency 30 70...

Page 11: ...DKG 175 User Manual V 1 24 07 2017 11 DATAKOM Electronics Ltd Tel 90 216 466 84 60 Fax 90 216 364 65 65 e mail datakom datakom com tr http www datakom com tr 8 CONNECTION DIAGRAM...

Reviews: