background image

15

WWW.RAPIDRH.COM

WAGNER METERS

1.  Carefully remove the screws near the top with a 

small Phillips head screwdriver.

2.  Tip the DataGrabber with Bluetooth upside down 

and tap the bottom of the unit carefully to dislodge 

the battery into your palm.

3.  Place the battery (replaceable CR 1/3N) within the 

well positive side up. (Note: the battery text should 

be visible.)

4.  Insert the battery until it stops. Be careful to avoid 

using excessive force.

5.  Replace the battery compartment cover and 

carefully re-install the two screws using a small 

Phillips head screw driver.

BATTERY

DataGrabber with Bluetooth

Removing and Replacing the Battery

1

2

Summary of Contents for Rapid RH L6

Page 1: ......

Page 2: ...OF CONTENTS Introduction Installation DataMaster L6 App Getting Started Connection Configuration Uploading Storing Sensor Data Removal Battery Troubleshooting Product Specifications 1 3 5 7 10 12 13 15 17 17 ...

Page 3: ...a microchip built into the sensor to store time and date stamped RH and temperature readings on a periodic basis for days weeks or even months at a time while you are away from the job site Both the DataGrabber with Bluetooth and the DataGrabber perform the same automated data gathering tasks They differ in how they communicate to your smartphone or other mobile device The DataGrabber with Bluetoo...

Page 4: ...ta keep a running clock of acclimation time download the time and date stamped readings to your smart device and generate and send reports Your DataGrabber device can be used to collect and store up to 512 time and date stamped RH and temperature readings on an L6 sensor The data you collect can help you gain a better understanding of the drying process as well as the dynamics that may be affectin...

Page 5: ...6 Smart Sensor previously installed in concrete Notice that your DataGrabber has nine small protruding metal connectors at the base Be sure to orient the base downward when you insert the DataGrabber into the L6 sleeve This is required to obtain a connection with the L6 Smart Sensor These pictures show what the DataGrabber with Bluetooth and the DataGrabber look like when installed correctly INSTA...

Page 6: ...4 WWW RAPIDRH COM WAGNER METERS DataGrabber fully and correctly inserted into L6 sensor ...

Page 7: ... with the DataMaster L6 app At this site you can choose a username and password This also becomes the username and password that you use for logging in to the DataMaster L6 app Next download the free DataMaster L6 app to your smart device ThisappisavailableonlineinbothiOSandAndroid versions at the Apple App Store and Google Play ...

Page 8: ...watch a video tutorial It s highly encouraged to watch this tutorial to ensure proper usage but if not you can also choose to skip the tutorial which takes you to the Total Reader Quick Reading screen shown below The DataMaster L6 app gives you many options for viewing saving and attaching your data to reports More information about using the app is available at https www wagnermeters com support ...

Page 9: ...uetooth a wireless connection is obtained when it is within Bluetooth range of your mobile device For the DataGrabber without Bluetooth usetheRapidRHTotalReaderwiththeDataGrabber to connect wirelessly to your mobile device CONNECTION Next with the DataMaster L6 app open on your mobile device click on the Menu icon three horizontal bars located in the upper right hand corner of the screen Then choo...

Page 10: ... up window will appear on the RH Reading screen if detecting an installed DataGrabber device for the first time IMPORTANT You must connect the Total Reader with the DataGrabber TWICE for it to start working The first time initializes the DataGrabber device and the second time verifies that the device is taking readings If you transfer the DataGrabber to a new L6 Smart Sensor you will need to repea...

Page 11: ...9 WWW RAPIDRH COM WAGNER METERS Example of reading results on DataMaster L6 app Pop up window will appear if using for the first time ...

Page 12: ... for configuration if the Settings button is green If the Settings button is grey you may need to troubleshoot your device see the Troubleshooting section on pg 17 Next click the green Settings button In approximately 20 seconds or less the Device Settings screen for that DataGrabber will appear as shown below CONFIGURATION Device Name The device name can be up to 12 characters long NOTE There wil...

Page 13: ...nsor For the DataGrabber it takes up to one minute to turn off after removal from an L6 sensor If inserted into a new sensor within that minute the DataGrabber will not detect the move until the next reading is taken For the DataGrabber with Bluetooth the process of turning off the device after removal occurs much quicker about 5 seconds Log Interval In addition to the reading captured grabbed whe...

Page 14: ... Start button to signal to the DataGrabber to begin the acclimation time NOTE The clock in the DataGrabber will automatically synchronize to the clock on your mobile device After you have configured your DataGrabber device to collect RH test data for you automatically you can return to the job site later to upload and store your data on your mobile device Uploading data Select your DataGrabber dev...

Page 15: ...RS 1 2 To remove the DataGrabber or DataGrabber with Bluetooth from the L6 Smart Sensor sleeve use the included removal tool as shown to carefully extract your device without damaging it REMOVAL Removal of DataGrabber with Bluetooth ...

Page 16: ...14 WWW RAPIDRH COM WAGNER METERS 1 2 Removal of DataGrabber without Bluetooth ...

Page 17: ...ge the battery into your palm 3 Place the battery replaceable CR 1 3N within the well positive side up Note the battery text should be visible 4 Insert the battery until it stops Be careful to avoid using excessive force 5 Replace the battery compartment cover and carefully re install the two screws using a small Phillips head screw driver BATTERY DataGrabber with Bluetooth Removing and Replacing ...

Page 18: ...e holes on the back to coax the battery out 3 Place the battery Replaceable CR1025 within the well positive side up the text should be readable Insert the battery until it stops Be careful to avoid using excessive force 4 Replace the battery compartment cover by guiding the arms of the cover inside the slot and pushing until the cover snaps into place 1 2 DataGrabber Removing and Replacing the Bat...

Page 19: ... temperature data If the Total Reader displays data but the app shows TR and not DG for the device type then the DataGrabber battery may be the problem Ensure that the battery is seated properly or replace the battery as needed TROUBLESHOOTING PRODUCT SPECIFICATIONS Replaceable CR 1 3N Battery Life 1 5 plus years although this will vary depending on usage Storage 512 data points Dimensions 1 25 4 ...

Page 20: ...red in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without the prior written permission of the publisher The information in this document is subject to change without notice Wagner Meters 326 Pine Grove Road Rogue River OR 97537 Worldwide Toll Free 888 266 7756 The RAPID RH L6 DataGrabber is registered under U S Patent 903...

Reviews: