DataComm 50-3321-WH-KIT Instruction/Installation Sheet Download Page 1

 

 

 

 

 
 
 
 
 
 
 
 
 
Parts Included:  

1. 

Recessed Cable Plate with Recessed Power Outlet 

2. 

Single Gang Recessed Cable Plate 

3. 

Old Work Electrical Box 

4. 

Single Gang Low Voltage Mounting Bracket 

 

Tools Needed:  

1. Drywall 

saw 

2. 

6 Ft. tape measure 

3. Pencil 
4. Screwdriver 

 

Use DataComm Electronics’ Flat Panel TV Cable Organizer 
Remodeling Kit with Power Outlet to install power and hide 
unwanted audio/video (A/V) cables behind your flat panel TV 

(see Figures 1 & 2)

 

To Install Recessed Cable Plate with Power 

Outlet with a Flat Panel TV Bracket 

 
Installation Instructions for New Construction: 

 
1. 

Have a licensed electrician install a power outlet on the 
wall at the location of the flat panel TV.   

2. 

Once power has been turned off to the circuit, remove 
the receptacle and wall plate installed by your electrician.   

3. 

Align the left side of the template supplied below over the 
left side of the electrical workbox then trace the opening 
needed for recessed cable plate.   

4. 

Connect the electrical wires to the back of the receptacle 
on the Recessed Cable Plate (RCP) with Recessed 
Power Outlet.  Connect the hot line (black) wire to the 
brass colored terminal or screw and the neutral (white) 
wire to the silver colored terminal or screw.  Be sure to 
connect the grounding (green) or bare grounding wire to 
the green colored terminal screw 

(see Figure 3)

.   

5. 

For shock protection, this UR, UL recognized component 
receptacle must be properly grounded.   

6. 

Caution – use copper wire only with this receptacle. 

 

See Final Instructions for New & Retrofit Installation. 

 
Installation Instructions for Retrofit Only: 

 
1. 

Determine the location of your flat panel TV mounting 
bracket.  Using the template supplied 

(see page 2)

, allow 

for location of the stud when tracing the opening needed.   

2. 

Using a drywall knife, cut a hole in the drywall the size of 
the template.   

3. 

Insert a single gang retrofit workbox 

(see Figure 2)

.  

Securely fasten the workbox to the wall.   

4. 

Switch the appropriate circuit breaker OFF or remove 
fuse(s) before wiring.  Run a source of power to this 
workbox. Connect hot line (black) wire to brass colored 
terminal or screw and neutral (white) wire to silver 
colored terminal or screw.  Be sure to connect grounding 
(green) or bare grounding wire to green colored terminal 
screw 

(see Figure 3)

.   

5. 

For shock protection, this UR, UL recognized component 
receptacle must be properly grounded.   

6. 

Caution – use copper wire only with this receptacle. 

 
See Final Instructions for New & Retrofit Installation. 

 

 

 
 

 
 
 
 
 
 
 

 

DataComm Electronics, Inc. 
6349 Peachtree Street 
Norcross, GA  30071-1725 
888.223.7977 
770.662.8205 
www.datacommcableorgnizer.com

 

Instruction / Installation Sheet    

DataComm Electronics 50-3321-WH-KIT Flat Panel TV Cable Organizer Remodeling Kit with Power Outlet 

 

  Figure 1 – Front View 

Figure 2 – Back View 

  50-3321-WH-KIT 

                                   Page 1 of 3

  

 

 

 

 

 

                        

3/23/10 Rev. 5 

Reviews: