DataComm Electronics 45-0041-WH Instruction/Installation Sheet Download Page 1

Use DataComm Electronics’ Recessed Low Voltage Media Plate with Duplex Surge Suppressor to install low voltage cables behind your flat panel TV, your 

amplifier or other audio and video devices.  This media plate can be installed upright or sideways.   

IMPORTANT INSTRUCTIONS:

   

This product is designed for retrofit work only because the old workbox cannot be attached to a stud.   

WARNING:   

Before installing this product, be sure the power is off by switching the circuit breaker to off or removing the fuse(s).  Test the power to make sure 

the power is off. Be sure to install the Media Plate with Duplex Surge Suppressor in accordance with the National Electrical Code (NEC) and local 

codes. 

Installation Instructions: 

Fig. 1 

Top view - shows needed space between the drywall and the studs. Receptacle side of the media plate must be 3” from the stud but no more than 5” 

(review picture carefully).

Fig. 2 

Using the template supplied (see page 2 of instruction sheet), trace the opening needed.  Using a drywall knife, cut a hole in the drywall the size of the 

template. See Figure 1 before tracing your opening. 

Fig. 3

 

Run the source of power to the included workbox. 

Fig. 4

 

Using the supplied surge suppressor, connect the Recessed Media Plate to the piece of 12/2 or 14/2 with ground UL approved building wire. Connect 

Fig. 5

 

Now use the four screws provided to secure the work box to the mounting studs on the backside of the of the media plate. 

Fig. 6

 

Pull all video and audio cords through the recessed opening.  Starting with the receptacle side of the media plate, slowing slide the plate into the 

opening. Swing the opposite side of the plate into position until the entire media box is flush with the wall. Now screw down the screws with wings; 

these wings fasten tightly against the back of the drywall. Switch on the circuit breaker to on or insert the fuse(s). Plug all necessary video and audio 

cables. Install your flat panel TV mounting bracket per the flat panel TV bracket manufacturer’s instructions. 

DataComm Electronics, Inc. 

6349 Peachtree Street 

Norcross, GA  30071-1725 

888.223.7977 

770.662.8205 

www.datacommelectronics.com

Instruction / Installation Sheet

DataComm Electronics 45-0041-WH Recessed Low Voltage Media Plate with Duplex Surge Suppressor 

        Parts Included: 

1.  45-0041-WH Recessed Low Voltage Media Plate  

2.  Old Work Electrical Box with 4 mounting screws 

3.  15 Amp/125 Volt Duplex Surge Suppressor 

5.  Four (4) Screws 

        Tools Needed: 

1.  Drywall Saw 

2.  6 Ft. Tape Measure 

3.  Pencil 

4.  Phillips Screwdriver 

 Fig. 3

Fig. 1

REV. 11/12/2019

Page 1 of 3

Fig. 4

   Fig. 6

the hot line (black) wire to the brass colored terminal screw and neutral (white) wire to the silver colored terminal screw. Be sure to connect the grounding 

(green) or bare grounding wire to the green colored terminal screw. 

 For shock protection, this UR, UL recognized component receptacle must be 

properly grounded. Caution – use copper wire only with this receptacle. Once you have wired the surge suppressor, screw the suppressor into the 

work box until the receptacle is firmly secured.      