![Data Video BC-50 Instruction Manual Download Page 54](http://html.mh-extra.com/html/data-video/bc-50/bc-50_instruction-manual_511269054.webp)
54
10. VISCA Command List
10.1. Camera-Issued Messages
Ack/Completion Message
Command
Function
Command
Packet
Comments
ACK/Comletion
Messages
ACK
z0 4y FF
(y: Socket
No.)
Return when
the command
is accepted.
Completion
z0 5y FF
(y: Socket
No.)
Return when
the command
has been
executed.
z = Camera A 8
Error Messages
Command
Function
Command
Packet
Comments
Error
Messages
Syntax Error
z0 60 02 FF
Returned
when the
command
format is
different or
when a
command with
illegal
command
parameters is
accepted.
Command Buffer
Full
z0 60 03 FF
Indicates that
two sockets
are already
being
used(executing
Summary of Contents for BC-50