Operating by the LED display mode 1 ((Reference the figure 8): 

1.

 

ON/OFF BUTTON---- Turn ON  this button to supply power to the UPS  outlets. To switch off power to the 

UPS outlets turn OFF the switch. This switch is situated on the front panel of the UPS. 

2.

 

AC NORMAL INDICATOR (Green light continuous) ---The UPS is supplying conditioned utility power to 

its outlets. 

3.

 

CHARGING INDICATOR (yellow light continuous) ---The UPS is supplying conditioned utility power to its 

outlets and the battery is charging. 

4.

 

BACKUP INDICATOR (red light slow blinking) ---The indicator starts slow blinking when utility power is 

outside acceptable limits. The battery is powering the UPS outlets.   

5.

 

SLOW  BEEPPING----A  one  second  duration  tone  is  sounded  two  seconds  after  utility  power  loss  has 

occurred. The UPS will continue to run with an audible alarm until a low battery condition is reached. 

6.

 

LOW  BATTERY  INDICATOR  (Red  light  fast  blinking)  ---The  indicator  starts  fast  blinking  whenever  the 

battery is near the end of its runtime. 

7.

 

FAST  BEEPING----The  UPS  is  near  the  end  of  its  battery  runtime  promptly  save  your  data  and  exit  all 

applications and shutdown the operating system. 

 

 

Operating by the LED display mode 2 ((Reference the figure 9):

 

1.

 

ON/OFF BUTTON ----Turn ON this button to supply power to the UPS outlets. To switch off power to the UPS 

outlets turn OFF the switch. This switch is situated on the front panel of the UPS. 

 

2.

 

AC  NORMAL  INDICATOR  (Green  light  continuous)  ---The  UPS  is  supplying  conditioned  utility  power  to  its 

outlets. 

 

3.

 

BACKUP  INDICATOR  (yellow  light  slow  blinking)  ---The  indicator  starts  slow  blinking  when  utility  power  is 

outside  acceptable  limits.  The  battery  is  powering  the  UPS  outlets.  The  expected  runtime  for  a  typical  personal 

computer (PC) is about 10 to 20 minutes. 

 

4.

 

SLOW BEEPPING----A one second  duration tone is sounded two seconds after  utility power loss has  occurred. 

The UPS will continue to run with an audible alarm until a low battery condition is reached. 

 

5.

 

FAULT INDICATOR (Red light fast blinking) ---The indicator starts fast blinking whenever the battery is near the 

end of its runtime. 

6.

 

FAST  BEEPING----The  UPS  is  near  the  end  of  its  battery  runtime  promptly  save  your  data  and  exit  all 

applications and shutdown the operating system. 

 

Manual Shutdown 

When the UPS is operating on battery the procedure below can be performed to conserve battery charge and not allow 

the connected equipment to have power removed without being properly shut down.. 

1.

 

Save important working files. 

2.

 

Exit all applications 

3.

 

Exit the operating system 

4.

 

Shut down the connected equipment. 

5.

 

Turn off the UPS ON/OFF Switch which is situated on the front panel of the UPS. 

 

 

 

 

 

 

Summary of Contents for DT-UPS-500

Page 1: ...For assistance contact our DataTronix Technicians at 610 429 1511 DT UPS SERIES DT UPS 500 DT UPS 1200 ...

Page 2: ...the positive and negative electrodes of battery Otherwise it may cause electric shock or fire 6 Do not plunge or insert any objects into the air vents and other inlets 7 Do not store or use the device in the following environment l Where there is inflammable gas corrosive agents or heavy dust l Where the temperature is very high or low above 40 104 F or below 0 32 F or the humidity is very high mo...

Page 3: ...ventilated area away from direct sources of heat Leave at least 100mm clearance all around the UPS to provide adequate ventilation Reference figure 1 Figure 1 Figure 2 The UPS is intended for indoor use only Although your UPS is very rugged its internal components are not sealed from the environment Please kindly note the following Reference figure 2 Avoid direct sunlight Avoid excessive heat Avoi...

Page 4: ...HOULD BE TAKEN TO AVOID EXCESSIVE TEMPERATURE AROUND THE UPS WHICH COULD ALSO RESULT IN REDUCING SERVICE LIFE OF THE BATTERY TO ACHIEVE MAXIMUM SERVICE LIFE FROM THE BATTERY THE ABOVE INSTRUCTIONS SHOULD BE FOLLOWED The UPS battery charges whenever the UPS is connected to utility power is switched ON It typically requires twelve hours to charge fully Operating runtime is reduced until the battery ...

Page 5: ...Turn ON this button to supply power to the UPS outlets To switch off power to the UPS outlets turn OFF the switch This switch is situated on the front panel of the UPS 2 AC NORMAL INDICATOR Green light continuous The UPS is supplying conditioned utility power to its outlets 3 BACKUP INDICATOR yellow light slow blinking The indicator starts slow blinking when utility power is outside acceptable lim...

Page 6: ...ns input Output voltage range battery mode 110Vac 120Vac 220Vac 230Vac 5 Square wave Output frequency range battery mode 50 60 1Hz frequency self adapt system Battery No load protection Auto protection The UPS will automatically shut down after 2min no load detected Transfer time 10ms Battery backup time 6Min half load Battery protection Auto protection The UPS will automatically shut down when ba...

Page 7: ...line Check input power at end of power cord and wall socket Otherwise call for service UPS suddenly turns to battery mode in spite of utility line present Rear panel input fuse open Reduce the load and replace fuse with same rating Input utility line too high or too low Check input line voltage Frequency out of range Check input frequency Single beep Normal UPS operation This is not a fault The UP...

Page 8: ...on act of foreign enemies hostilities regardless of whether war is declared civil war rebellion revolution insurrection military or usurped power or confiscation terrorist activities nationalization government sanction blockage embargo labor dispute strike lockout or interruption or failure of electricity air conditioning or humidity control internet network or telephone service The warranties giv...

Reviews: