Chapter 1
34
In measure mode only, you can measure the pulse width of a signal by specifying the edges as
one of the following:
• Start edge = rising; Stop edge = falling
• Start edge = falling; Stop edge = rising
Note:
In measure mode and continuous measure mode, the internal C/T clock is used to
calculate the interval of the signal between the specified start and stop edges. The pulse
width and period count are automatically set to 0. In measure mode, you can specify the
polarity of the output signal during and after the measurement.
Pulse Output Parameters
DT9840 Series modules can output pulses from each counter/timer.
lists the pin
assignments of connector J17 on the module that correspond to the pulse output signals.
You can specify the following pulse width parameters using software:
• Polarity, described below
• Period count, described on
• Pulse width count, described on
Polarity
You can specify one of the following values for the polarity of the pulse output signal:
•
Active high (low-to-high transitions)
– The high portion of the total pulse output period
is the active portion of the counter/timer pulse output signal.
•
Active low (high-to-low transitions)
– The low portion of the total pulse output period is
the active portion of the counter/timer clock output signal.
Table 4: Pulse Output Signals on the DT9840 Series Modules
Counter/Timer Pulse Output Signal
J17 Pin Number
Counter Output 0
5
Counter Output 1
3
Counter Output 2
1