Table 30: Default Control Values for Line-Scan Mod e
Control Name
Value
OLC_FG_CTL_INPUT_FILTER
OLC_FG_FILT_AC_NONE
OLC_FG_CTL_BLACK_LEVEL
0
µ
V
OLC_FG_CTL_WHITE_LEVEL
700,000
µ
V
OLC_FG_CTL_CLAMP_START
90 pixels
OLC_FG_CTL_CLAMP_END
95 pixels
OLC_FG_CTL_SYNC_SENTINEL
FALSE
OLC_FG_CTL_FRAME_WIDTH
1000
OLC_FG_CTL_FRAME_HEIGHT
1
OLC_FG_CTL_CLOCK_SOURCE
OLC_FG_CLOCK_INTERNAL
OLC_FG_CTL_CLOCK_FREQ
1,000,000 Hz
OLT_FG_TRIGGER
OLC_FG_TRIGGER_NONE
OLC_FG_CTL_ILUT
0
OLC_FG_PC_SRC_ORIGIN_X_LIMITS
0
OLC_FG_PC_SRC_ORIGIN_Y_LIMITS
0
DT3152_INPUT_CTL_GAIN
100 (gain of 1)
DT3152_INPUT_CTL_REFERENCE
700,000
µ
V
DT3152_INPUT_CTL_OFFSET
0
µ
V
Master Clock Divider Value
1
Clock Pulses for LS_SYNC_LO_TO_HI
0
Clock Pulses for LS_SYNC_HI_TO_LO
1
Clock Pulses for LS_INTGR_LO_TO_HI
198
Clock Pulses for LS_INTGR_HI_TO_LO
595