Data Link CW232 Manual Download Page 1

Simple User's Manual

   

Ver1.1

         

2006.3    DATA LINK Co., Ltd 

CW232

·

CW232/V

·

CW422

Compact Watch RS232C/RS422 Analyzer

 

 

Introduction

 

Thank you for your choosing our RS232C/RS422 Analyzer 

CW232(V)/CW422

.  

This manual will give you some notices about how to use this product. 

Please read the content before you use the product. 

Please agree to omit (V) of CW232/V in the following sentences, and to unite it only to the mark 

named 

CW232/CW422

 

Package Contents

 

 

Simple manual (this book) 

 

Install CD-ROM 

 

CW232/CW422 main body 

 

USB cable

 

 

Please contact our Sales Department though it descends to the packing of the product with 

scrupulous care if any of the above items of the package is missing. 

System Requirement

 

Correspondence OS: Windows98SE / 2000 / XP  

Recommended environment:   

CPU _______Intel Pentium / Celelon 800MHz or above 

RAM ______256 MB or above 

HDD_______300 MB free space or above 

USB _______USB1.1 or above 

Others______External Graphic Card instead of the built-in one is recommended. 

When the application program is installed, the CD-ROM driver is necessary. 

Notification 

 

Memory and hard disk capacity necessary for operating the program might be different depending on 

the system environment used. 

 

It should be tested in the above-mentioned, recommended environment, otherwise it probably      

exists some instance that operation cannot be completely guaranteed according to customer's 

environment. 

 

Various specifications of the product are subjected to variation without a previous notice. Please    

acknowledge it beforehand. 

 

Please not connect it to interfaces other than USB and RS232C/RS422.

It cause damage and fire, etc.

 

 

Please not put it on moisture, dust, lamp soot or damp.       

         It causes fire etc. 

 

Please not use or leave it in the place of the high temperature  like  the  place  where  direct        

sunshine in close contact with the heater strikes.                  

It causes fire etc.

 

 

Please not put the foreign body internally to remodel it.       

 

    It causes fire, the electric shock, and the injury.

 

 

 

Please not touch by a wet hand.

                                                              It causes the electric shock. 

 

Please remove all cables at once and not go on using when generation of heat is felt or abnormality 

such as smelling to strangeness is confirmed by any chance. Please contact the shop of purchase.

 

Summary of Contents for CW232

Page 1: ...m is installed the CD ROM driver is necessary Notification Memory and hard disk capacity necessary for operating the program might be different depending on the system environment used It should be tested in the above mentioned recommended environment otherwise it probably exists some instance that operation cannot be completely guaranteed according to customer s environment Various specifications...

Page 2: ...SB socket on the PC by USB cable When the following dialog box is displayed click Next button When Please select the retrieval method dialog box is displayed please select Search for the best driver for your device and click Next button When the following dialog box is displayed please select CD ROM driver and click Next button ...

Page 3: ...ation Windows XP After insert attached CD ROM in PC connect CW232 CW422 main body to the USB socket on the PC by USB cable When the following dialog is displayed select Install the software automatically Recommended and click Next button It will be up to Completing the Found New Hardware Wizard according to the dialog message Application program CW232 422 installation When Setup exe is double clic...

Page 4: ...32 422 dialog box is displayed click Next button In addition the following dialog boxes are displayed Please select a setup type screen Complete C is selected usually Ready to install the program the screen When Install I was clicked the installation begins InstallShield Wizard completed the screen click Finish F and installation ends CW232 422 is started from a start menu or a desktop icon ...

Page 5: ...splayed The count bar The number of data receptions from the equipment connected with the CH1 side is displayed in TXD The number of data receptions from the equipment connected with the CH2 side is displayed in RXD RTS high displays the frequency that RTS is changed from Busy into Ready RTS below displays the frequency that RTS is changed from Ready into Busy The change frequency of CTS DSR high ...

Page 6: ...starting 5 It is assumed the state that can be communicated by turning on the power supply of the device at monitored both ends 6 The CW232 422 application program is set and it is assumed the state of the monitor beginning 7 The communication that wants to be actually monitored between devices at both ends begins Attention Please connect both sides in correct way Please note the signal polarity o...

Page 7: ...enu Settings COM Settings Baud rate 50 100 110 150 200 300 600 1200 2400 4800 9600 14400 19200 28800 38400 57600 76800 115200 Under baud rate whether data can be monitored depends on the processing performance of PC According to the processing performance of PC there is a possibility of defeating Data length 7 or 8 Parity bit None Odd or Even Stop bit 1 or 2 Setup display mode Menu Settings Displa...

Page 8: ...data does somewhat back and forth When the monitor stop button is clicked the monitor stops The monitor is stopped and the collection data is analyzed The position where the monitor data is displayed can be moved by the scroll bar After the monitor stops the collection data is analyzed If data is indicated and clicked with the mouse pointer the position of specified data is displayed The monitor d...

Page 9: ...ox is displayed When this message is displayed analyzer application program CW232 422 is ended once Please confirm that CW232 CW422 and PC are correctly connected with an attached USB cable Analyzer application program CW232 422 is started again After starting analyzer application CW232 422 the application and CW232 CW422 cannot communicate because the USB cable comes off the following dialog box ...

Page 10: ...upper part of the main body becomes a green light after red lights It is normal CW232 CW422 is thought of abnormity when it is not lighting such LED Please not go on using and contact our user support section This LED blinks in green while monitoring it normally When the parity error is detected during monitoring LED becomes blinking red ...

Page 11: ...Externals chat ...

Page 12: ...deling breakdown because of repair and damage It breaks down or it damages it to fires such as a fire the earthquake and lightning Breakdown and damage that originates in equipment outside our product connected with our product 4 In the following cases it is not possible to repair even for a fee When the repair price exceeds a new product price by the state of the breakdown like the PCB substrate ...

Reviews: