PLR5000 Modem Configuration
The PLR5000 allows you to set several parameters to suit your particular application. All adjustments are
done through the PLR5000 setup program, a user interface that eliminates the need for setup diskettes, DIP
switch settings or custom software.
To access the configuration menu, connect the radio modem to any terminal program with port settings of
19.2Kbaud, 8 data bits, no parity and one stop bit. With the modem connected to the PC running the terminal
program, press the Configure button located behind the pinhole next to the DB-9 connector on the front of the
modem. While any terminal program that can be set to 19200 baud will work, examples for this user guide
were generated using the Microsoft Windows 2000 application “HyperTerminal.”
Note:
When using HyperTerminal, set Handshaking to none.
Table 1:Terminal Settings
Parameter Setting
Baud Rate
19200
Data Bits
8
Parity None
Stop Bits
1
Flow
Control
None
When the setup program is invoked, the “O” LED on the PLR5000 front panel will flash once when the
Configure button is pressed and the “C” LED will remain on for the entire time the radio modem is in setup
mode.
The main menu provides the radio modem’s unique call book number and the set of choices for editing the
operational parameters and viewing
the
performance
data.
Figure 1: Main Menu