DD580, DD565, DD530, and DD510 Systems
57
Installation
•
Dual port optical 1Gb (1000 BASE-SX) multi-mode fiber Ethernet PCIe NIC with LC
connectors
Ethernet Failover and Aggregation is not supported in DD OS 4.3.x or earlier.
The DD580, DD580g, DD565, DD530 and DD510 systems support up to one optional single port 2
Gbps VTL Fibre Channel PCI-X HBAs. A second VTL PCI-X card is not supported.
Installation
DD580, DD580g, DD565, DD530, and DD510 Data Domain systems consists of the tasks listed
below. For site hardware requirements, see “Power and Weight Specifications” on page 18.
Note
“Data Domain Gateway Systems”contains instructions for installing and configuring Data
Domain Gateway systems (for example, DD580g systems).
•
Set up the system hardware. See the rack installation instructions supplied with the system.
•
To use DHCP with Ethernet interfaces, configure the DHCP server with the appropriate Data
Domain system information. To configure a Data Domain system using an Ethernet interface,
you must provide DHCP information for at least one interface. The alternative is to use a serial
console or a keyboard and monitor. See “DHCP Server” on page 60 for more details.
•
Set up a serial console or a monitor and keyboard if you are not using an Ethernet interface for
configuration.
Caution
The two side brackets on the system’s front faceplate (see Figure 23 on page 59) cannot
support the weight of the system in a rack. Support the system with the slide rails that
are delivered with the system.
1.
Mount the system in a 3U space in a 19-inch, four-post rack using the slide rails provided by
Data Domain. Any other means of mounting the system must be rated for at least 100 pounds
(45 kilograms).
Do NOT install a system in a two-post rack.
a.
Open the slide rails package that ships with the system.
b.
Using the slide rail instruction and rack template documents that are included with other
system documentation, mount the inner rails onto the system.
Note
The slide rails can accommodate a front-to-back rail depth of 28 inches (710 mm) to 33.67
inches (855 mm).
2.
Mount the outer rails onto the rack.