Problems checking and Electrical
performance
Resolve the problems
The error code will be displayed on the screen if the heater dose not work
.After the problem is resolved , reset the Run button
'LVSOD\
5HDVRQ
$SSURDFK
No Display
●No power / power plug out
●Check the power plug
ER01
ER02
ER03
●No tank or not placed flatly
●Place the fuel tank again .
● Make sure the heater is placed vertically
●The heater is tilted or hitted
●Not fired after working for 5 minutes
ER05
ER06
ER07
ER08
ER09
ROF
●Set fire fail
● Detect the flame ignition voltage
when the heater is not fired .
ROP
KOF
FLOF
KSOF
●The chimney probe is short circuit
KSOP
ER14
●The cooling time is more than 3
minutes .
●Abnormal combustion of kerosene
●The chimney temperature is too
high
●The core temperature is not
measured when the heater works .
●The room temperature probe is short
circuit
●The room temperature probe opens
circuit .
●The oven temperature is short
circuit
● The flame probe is short circuit .
●Check whether the ignition furnace core is heat
●Check the fuel tank if water on it or not
●Please Check flame probe whether there is dirts .
● If the chimney probe has dirts .
●check whether the kerosene is pure or
not.
●Check whether the furnace core probe
works or not .
●Check whether the room temperature
probe works or not .
●Check whether the oven temperature
works or not
●Check whether the flame probe is dirty or
not
●Check whether the room temperature
probe works or not .
Specification:
Forced ventilation, open-end
Category:
v a p o r i z a t i o n - t y p e , f o r c e d
convection
Fuels
lamp oil or kerosene
Fuel Consumption:
0.08~0.33L/H
Heat:
3.2 or 3.5KW
Fuel tank capacity:
/
Rated Voltage
AC220~240V
Frequency:
50~60Hz
Consumption power:
Igniting state:
300W
Working state:
28W
0DGHLQ&KLQD
Electrical performance of DS-350ER
SHANGHAI DASHAN
,1'8675,(6&2/7'
The chimney probe is open circuit
●Check whether the chimney probe is
dirty or not
Summary of Contents for DS-350