Manual del Usuario
/ DASnet Rack 99 230V /
User’s Manual
13
ANNEX II : DASnet cables
1 Orange-White Audio+ 2
2 Orange Audio- 3
3 Green-White Audio Earth 1
4 Blue
5 Blue-White
6 Green Data Earth 1
7 Brown-White
Data- (A) 3
8 Brown Data+ (B) 2
etherCon
XLR
It is very important to use the system with the intended cables to prevent electromagnetic
interferences between the analog audio signal, the DASnet data and the power. Be sure to
check the specifications provided by the cable manufacturer. It is also especially important
when installing connectors yourself, to note that when termination is not accurate, a cable
will be unable to achieve its maximum performance and could have interferences.
There are 4 different types of cables.
-
The main feeds which include power and a STP, CAT7 cable. These cables are named
eCP_xx
(xx refers to cable length).
-
Power Links between cabinets.Cable code
Plink1_09
-
Links for RoadNet series. Power+STP CAT7. eCPk_1/eCPk_5
-
The links between cabinets (aero40A/Convert15A/LX-218CAnet), which are STP CAT7
cables. Cable code
eC_09
The main feed cable eCP_xx has the following structure:
AL Shield
2
2
ecP_xx: Power cable 3x2.5mm + CAT7 4x (2 x 0.14mm )
Jacket
Jacket
STP CAT 7 cable with Aluminium
Shield for each individual pair
and a main aluminium Shield.
The main Shield has to be
soldered
to
the
etherCon
housing.
The eC_09 cable is a CAT5e
cable with global Aluminium
Shield.
Important
The pin out of the EtherCon to XLR is the following on the eCP cables: