Information for whoever carries out the checks 
 

Gearmotor: 
The mechanism is maintenance free and it is provided with permanent lubrication. Absolutely no rust 
must form on the output shaft. 
Fixings: 
Make sure that the fixing screws are all in the correct position and in perfect condition. 
Balancing by weights (e.g. in the sectional main doors): 
The door must be balanced in all the positions (see the door assembly instructions) when balancing is 
done with weights according to the procedures prescribed by the standards. 
Brake (if present): 
During the annual check perfect brake operation is to be ascertained. 
In the case of heavy wear of the brake pads, it is necessary to replace the complete brake. Before 
replacement, disconnect the cables connected to the electric card. 

 

 

TECHNICAL SPECIFICATIONS 

 

NOTE: all the technical characteristics indicated refer to a temperature falling between -5°C and 

+40°C. • 

DAS reserves the right to change all the modifications to the product it deems necessary at 

any time but keeping the functions and intended use unaltered. 
We recommend using 20 rpm gearmotors for doors with vertical movement with conical cable 
winder drum. 
For non-balanced sectional doors, we recommend using RDF series gearmotors with parachute 
device. 
When assembling gearmotors with 31.75 mm diameter shaft from the left, the tab is to be blocked 
only with a shoulder collar because fixing with a screw could break the shaft. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 

Summary of Contents for 008641

Page 1: ...BLE OF CONTENT General information 2 Safety standards 2 Installation rules 2 General danger warnings and preventive safety 4 Assembly instruction Fixing the mechanism 4 Emergency manual releases 5 Limit switch setting 6 Star Delta voltage connection 7 Annual check 7 Technical specifications 8 Technical dimensions 9 Declaration of conformity 9 ...

Page 2: ... and EN 13241 1 in particular which enable conformity of the automated functionality to be de cleared In the light of the above all work involving installation connection testing and maintenance of the product must be carried out exclusively by qualified and competent technicians INSTALLATION RULES Before commencing the installation check if the product is suitable for the de sired type of use If ...

Page 3: ...al capacities or who lack experience or knowledge unless supervised or trained in the use of the product by a person responsible for their safety Any children near the automation system must be kept under supervision to ensure that they do not play with it Do not allow children to play with the fixed control devices Keep remote control devices out of the reach of children The instructions shall co...

Page 4: ...l Insurance Institute for Industrial Accidents BGR 232 The static overturning moment is the maximum load allowed for the mechanism at the time the spring breaks The Mstat static overturning moment is calculated with the following formula Mstat Nm Wing weight N cable winder drum radius m Considering that two balancing springs can yield at the same time the Commission of experts about building devic...

Page 5: ...lose the door turning the handle The control voltage is reset and the door can again be activated electrically by removing the handle Manual chain operated emergency release fig 4 and 9 Movement to the right or left activates a microswitch that will cut out the voltage going to the reduction unit afterwards the main door can be opened or closed by pulling the chain After releasing the chain the vo...

Page 6: ...d by manually opening and closing the door with identical activation force in both directions The Evotronix magnetic limit switch is a positioning switch with absolute value for rolling shutters doors and main doors The assessment or setting of the final positions is carried out with gearmotors for doors During assembly simply insert the six pole plug Mechanical settings and positionings are not n...

Page 7: ...to the motor wire the ends of the windings as illustrated in fig 13 16 When fixing the motor cables pay attention that the cables are long enough to consent solid fixing to create a connection able to remain secure over time Pull the conductors to check if the connection is secure When switching over the motor for connection to a 3 x 230 V power grid it is necessary to also adjust the gearmotor 3x...

Page 8: ...g the annual check perfect brake operation is to be ascertained In the case of heavy wear of the brake pads it is necessary to replace the complete brake Before replacement disconnect the cables connected to the electric card TECHNICAL SPECIFICATIONS NOTE all the technical characteristics indicated refer to a temperature falling between 5 C and 40 C DAS reserves the right to change all the modific...

Page 9: ...Manual Sectional Door Drive 9 DAS Deutsche Antriebs und Steuerungstechnik GmbH Otto Hahn Str 3 48301 Nottuln Germany info das automation com TECHNICAL DIMENSIONS ...

Reviews: