7.3  CE Mark Certification 

 

The CE mark is the official marking required by the European Community for all Electric and Electronic 
equipment that will be sold, or put into service for the first time, anywhere in the European community.  It 
proves to the buyer or user that this product fulfils all essential safety and environmental requirements as they 
are defined in the European Directives. 
 
PVE400 is covered under the product certification Europe: 
 
Radio Spectrum :   EN 300 328 V1.7.1 (2006-10) 
EMC:  

 

 

 

EN 301 489-17 V1.2.1 (2002-08) 

Safety:   

 

 

EN 60950-1 2001 +A11: 2004 

Health:   

 

 

EN50360: 2001 (Specific Absorption Test – SAR) 

 
CE Marking on the product will grant access to the European Economic Area (EEA).  Some countries may 
require a declaration of conformity, please check with your sales team for details. 
 
The following is an example of the CE Marking on the product label:  
 
The alert symbol indicates that PVE400 is 

not

 certified to operate in France.  Outdoor use in France is restricted 

to 10mW EIRP for band 2454 -2483.5 MHz

 

 

 

 Note

:  

CE mark is not applicable if WMC7300 is assembled in the unit (PVE40049 model) 
 

7.4  CSA Mark Certification        

 

CSA Reference Number: 242519-2005519 
The enclosure is evaluated to UL50 and CSA94 standard type 4 environment rating for outdoor use. 
CAN/CSA-C22.2 No.60950-1-03 – Safety of Information Technology Equipment 
ANSI/UL 60950-1-2002 – Safety of Information Technology Equipment 
 
The 'C' and 'US' indicators adjacent to the CSA Mark signify that the product has been evaluated to the 
applicable CSA and ANSI/UL Standards, for use in Canada and the U.S., respectively. This 'US' indicator 
includes products eligible to bear the 'NRTL' indicator. NRTL, i.e. National Recognized Testing Laboratory, is a 
designation granted by the U.S. Occupational Safety and Health Administration (OSHA) to laboratories which 
have been recognized to perform certification to U.S. Standards. 

Copyright © 2007-2008 Darim Vision Co, All Rights Reserved

 

- 27 - 

Summary of Contents for VIDEOSPIDER PVE400 edition

Page 1: ...User s Guide Rev 1 3a May 30 2008 Copyright 2007 2008 Darim Vision Co All Rights Reserved...

Page 2: ...m Vision Co All Rights Reserved No part of this reference manual may be reproduced or transmitted in any form or by any means without the prior written permission of this company Throughout this manua...

Page 3: ...red connection configuration 12 3 2 2 Wireless connection configuration 14 3 3 VIDEO AND AUDIO CONFIGURATION 16 3 4 VIEWING VIDEO 17 3 5 MONITORING THE BATTERY STATUS 19 3 6 UPGRADING FIRMWARE 20 3 7...

Page 4: ...either an Incident Response Command Post or from a Central Operations Control Centre delivering real time video and audio information from outdoor environments back to a centrally managed control loc...

Page 5: ...output for camera power feed Up to 4 hours operating time on single Field replaceable battery Multi device Enterprise management from Darim s VideoSpider Console 1 2 Requirements The following are th...

Page 6: ...PVE400 USER S GUIDE 2 INSTALLATION STEPS This chapter describes the installation procedure of the PVE400 accessories Figure 2 PVE400 interface Copyright 2007 2008 Darim Vision Co All Rights Reserved 6...

Page 7: ...2 Installing the camera PVE400 is bundled with 1 3 Sony Ex View HAD CCD Hi res weatherproof bullet camera The camera comes with Fischer Automatic Latching Self Aligned 5 pin connector Gently plug and...

Page 8: ...rce 2 5 Battery charging The battery can be charged using an external charger optionally supplied p n PVE ECx or internally using bundled AC 12VDC power adapter PVE PS with AUX adapter The charging ti...

Page 9: ...this device may present a risk of fire or chemical burn hazard if mistreated Do not recharge disassemble heat above 60 C 140 F or incinerate Replace battery with Saft model 1S1P MP 176065 only Use of...

Page 10: ...e factory default configuration for Ethernet IP 192 168 1 250 static To access PVE400 for the first time using the wired connection PC must be on the same network subnet The network settings can be ch...

Page 11: ...he internal time clock can be adjusted to reference time server using the standard NTP protocol during boot time Most of Linux systems have NTP Daemon to synchronize time between machines The best opt...

Page 12: ...be automatically set accordingly to the connection The Ethernet IP mode drop down list allows you to select the IP configurations parameters DHCP Server PVE400 has an internal DHCP server and can pro...

Page 13: ...on the Network configuration page Disabled Ethernet adapter is turned off The Ethernet MAC address parameter is a read only one and shows unique MAC address of Ethernet adapter PVE400 All PVE400 devic...

Page 14: ...the Static IP Assignment mode enter the proper information for IP address Subnet Mask and Default Gateway if required The Network Name ESSID filed allows specifying the Network Name or Extended Servi...

Page 15: ...on Access Point Choose either TKIP or AES value using the WPA Encryption drop down list Selecting TKIP sets encryption cipher for WPA PSK while the AES selection sets encryption cipher for WPA2 PSK U...

Page 16: ...y but it will not exceed the specified value in this field The Video Encoder Target Rate parameter field serves for specifying maximum allowed bit rate for video compression It depends on the link qua...

Page 17: ...Frame Rate and Video Encoder Target Rate selection fields If any changes have been made on this page click the Apply button otherwise simply select other tab The Restart button will restart the stream...

Page 18: ...ption is using Darim s Video Spider software it can be purchased separately The Video Spider software will allow to monitor and record data from multiple PVE400 units The Video Spider software has Cli...

Page 19: ...maximum The device will normally operate until the battery is discharged down to 3 0V and then shutdown The rechargeable Lithium Ion battery rated with capacity 6 8Ah if discharged till 2 5V It means...

Page 20: ...r off on cycle is recommended after the upgrade procedure If the status after the upgrade reports an error check the network connection to upgrade site if it can be accessed from the network segment o...

Page 21: ...o stream LED will start blinking Yellow LED will start blinking if quality of connection degraded Red LED will start blinking if battery capacity below 10 and will be solid red when less than 5 remain...

Page 22: ...s added to the list all other devices are automatically prevented from accessing with the exception of those devices from the list To add a new trusted address click the Add button Using the Delete bu...

Page 23: ...gateway for them Example Ext device 1 PVE400 Ethernet side PVE400 Wireless side IP 192 168 1 2 IP 192 168 1 250 IP 172 31 1 200 MASK 255 255 255 0 MASK 255 255 255 0 MASK 255 255 0 0 GW 192 168 1 250...

Page 24: ...ential RMA information The nearest Darim s Regional Representative can be found at http www darimcctv com support pve_rep php Or send an e mail to usasales darim com The Regional Representative will b...

Page 25: ...manual failure of the end user to follow the maintenance procedures in the service manual for the Product where a schedule is specified for regular replacement or maintenance or cleaning of certain pa...

Page 26: ...correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the PV400 and receiver Connect the equipment into an outle...

Page 27: ...bel The alert symbol indicates that PVE400 is not certified to operate in France Outdoor use in France is restricted to 10mW EIRP for band 2454 2483 5 MHz Note CE mark is not applicable if WMC7300 is...

Page 28: ...pplicable in the European Union member states The WEEE marking on this product indicates that the product must not be disposed of together with household waste To prevent possible harm to human health...

Page 29: ...ition External power 10 16V DC 1 5A Dimensions 5 3 x4 45 x1 46 134x113x37mm Weight 1 65lb 0 75kG without caring case Operating temperature 4 F 104 F 20 C 40 C Humidity 0 95 Rating NEMA 4R IP66 8 2 PVE...

Page 30: ...hernet Rx Data 7 Ethernet Tx Data 8 RS232 ground 9 RS232 Rx 10 RS232 Tx Mating male connector Fischer S1031 A010 140 A V connector Pin Designation 1 Video in 2 Audio input 3 Audio ground 4 12V out 5 V...

Page 31: ...green 6 Ethernet 2 white orange 1 Ethernet 5 white brown 7 reserved 6 white green 3 Ethernet 7 orange 2 Ethernet 8 white blue 5 RS232 common 9 brown 8 RS232 Rx 10 blue 4 RS232 Tx Note Ethernet wired...

Page 32: ...y PVE RPC US US type Power cord for PVE PS PVE RPC EUR European type Power cord for PVE PS PVE RPC UK UK type Power cord for PVE PS PVE RPC AUS Australian type Power cord for PVE PS PVE VPS Vehicle DC...