![Darfon B09ULF Instruction Manual Download Page 12](http://html1.mh-extra.com/html/darfon/b09ulf/b09ulf_instruction-manual_3501272012.webp)
11 / 47
Parallel
machine CAN
communication
supplementary
instructions
RJ45-8P8C
2-3
Press a 120
ohm resistor in
2-3 pins for
parallel CAN
communication
matching
resistors
When multiple battery
boxes are combined for
CAN communication, an
8PIN crystal head with an
internal voltage of 120
ohms is inserted in the first
and last CAN
communication interfaces
for parallel CAN
communication matching
resistors. (The crystal
head with an internal
pressure of 120 ohms is
attached as an accessory
at the time of shipment)
DIP switch
1-4
The first 3 digits set the battery address and
the 4th digit sets the operating mode. The
"ON" side indicates "1" and the other side
indicates "0"
When the system is configured with a
battery, the 4th bit is set to “0” and the
first 3 bits are set to “000”.
When the system is configured with
multiple battery packs, the 4th digit is
set to “0”, and the first 3 digits are set to
“000, 001, 010, 011, 100, 101, 110, 111”
to indicate “Address 0~Address 7”.
For detailed description of the DIP
switch, refer to Section 3.2.3.