RadiCentre 2-slot and 7-slot specific:
A ‘LASER Code’ is required to activate the RadiCentre 2-slot and 7-slot systems. This
LASER code enables the power supply to all installed (LASER) modules.
(Please refer to Chapter 3.2 for the default laser code).
To prevent accidental activation of the LASER, an ‘Acknowledge’ button will appear
directly after the LASER ‘Start’ button is pressed. The LASER will only be activated if
this button is pressed within the ‘4 seconds timeframe’.
RadiCentre single-slot specific:
To start the RadiCentre 1-slot system (which has no touchscreen display),a specific activation
procedure combined with auditory warnings is used.
To activate the LASER in the RadiCentre Single, follow these steps:
1.
Press the ‘Start’ button on the back panel (of the RadiCentre) and hold it for at least
3 seconds.
2.
Five loud ‘beeps’ can be heard; four short beeps followed by one long beep.
3.
On the fifth ‘beep’ the LASER link is activated and the red ‘LASER ON’ LED (on the
RadiSupply card) lights up.
4.
Release the ‘Start’ button.
This means that:
If you want to interrupt the activation process, all you have to do is release the
‘Start’ button (before the fifth ‘beep’). The LASER will not be activated.
If you are interrupted during the activation process (and release the ‘Start’ button
by accident), the LASER will not be activated.
If you press the button by accident (and do not wish to activate the LASER), the
auditory warning will alert you to this action.
To prevent accidental activation of the LASER, an auditory warning will alert you of the
LASER activation procedure (if the ‘Start’ button is being pressed). To interrupt the
activation process, all you must do is release the ‘Start’ button.