DAPAudio ZoneControl MKII Product Manual Download Page 5

3

  Make sure you don’t use the wrong kind of cables or defective cables.

  Make sure that the signals into the mixer are balanced, otherwise hum could be created.

  Make sure you use DI boxes to balance unbalanced signals; All incoming signals should be clear.

  Make sure that the available voltage is not higher than stated on the rear panel.

  Make sure that the power-cord is never crimped or damaged. Check the system and the power-cord

from time to time.

  In system setup, the amplifier's output power must be 50%-100% more than the loaded

loudspeakers rated power.

  Please turn off the power switch, when changing the power cord or signal cable, or select the input

mode switch.

  Extreme frequency boosts in connection with a high input signal level may lead to overdriving your

equipment. Should this occur, it is necessary to reduce the input signal level by using the INPUT
control.

  To emphasize a frequency range, you don’t necessarily have to move its respective sliding control

upward; try lowering surrounding frequency ranges instead. This way, you avoid causing the next
piece of equipment in your sound path to overdrive. You also preserve valuable dynamic reserve
(“headroom”)

  Avoid ground loops! Always be sure to connect the power amps and the mixing console to the same

electrical circuit to ensure the same phase!

  If system is dropped or struck, disconnect mains power supply immediately. Have a qualified

engineer inspect for safety before operating.

  If the system has been exposed to drastic temperature fluctuation (e.g. after transportation), do not

switch it on immediately. The arising condensation water might damage your system. Leave the
system switched off until it has reached room temperature.

  If your Dap Audio device fails to work properly, discontinue use immediately. Pack the unit securely

(preferably in the original packing material), and return it to your Dap Audio dealer for service.

  Repairs, servicing and electric connection must be carried out by a qualified technician.

  For replacement use fuses of same type and rating only.

 

WARRANTY: Till one year after date of purchase.

OPERATING DETERMINATIONS

If this system is operated in any other way, than the one described in this manual, the product may suffer
damages and the

 

warranty becomes void.

Any other operation may lead to dangers like short-circuit, burns, electric shock, etc.

You endanger your own safety and the safety of others!

Improper installation can cause serious damage to people and property !

Summary of Contents for ZoneControl MKII

Page 1: ...ZoneControl MKII ORDERCODE D2107...

Page 2: ...n DAP Audio for more excellent audio products We design and manufacture professional audio equipment for the entertainment industry New products are being launched regularly We work hard to keep you o...

Page 3: ...DAP Audio ZoneControl MKII Product Guide Warning Safety instructions Operating Determinations Description Features Overview Backside Installation Set Up and Operation Set Up Connection Cables Mainten...

Page 4: ...ains with particular caution Never remove warning or informative labels from the unit Never use anything to cover the ground contact Never leave any cables lying around Do not insert objects into air...

Page 5: ...rve valuable dynamic reserve headroom Avoid ground loops Always be sure to connect the power amps and the mixing console to the same electrical circuit to ensure the same phase If system is dropped or...

Page 6: ...ND on every zone Exclusive design Separate master groups each for a different location Overview Fig 1 1 Gain range min max 2 High range 12 12 dB 3 Mid range 12 12 dB 4 Low range 12 12 dB 5 Pan range L...

Page 7: ...or 3 L R 22 Unbalanced L R and Rec Out L R for Zone 1 2 or 3 23 Light to Sound for Zone 1 2 or 3 24 For CH5 L8 L R and L7 L R 25 For CH4 L6 L R and L5 L R 26 For CH3 L4 L R and L3 L R 27 For CH2 L2 L...

Page 8: ...level using the gain control so that during the loudest passages the PEAK LED is just not lit but the SIGNAL LED lights constantly This basic channel setting leaves you at least 8dB headroom This mean...

Page 9: ...Gain control With the Gain control you can adjust the MIC input sensitivity while optimally matching the incoming signals to the mixer s internal operation level When dealing with very low input leve...

Page 10: ...it is not in complete isolation If you push the PFL button regardless of the Aux rotary control you will get the complete signal in your headphone monitors This is useful because the recording enginee...

Page 11: ...tion Before plugging the unit in always make sure that the power supply matches the product specification voltage Do not attempt to operate a 120V specification product on 230V power or vice versa Set...

Page 12: ...always to your advantage Periodically check that your cables are in good condition that they are correctly wired and that all their contacts are perfectly efficient a great number of problems faulty...

Page 13: ...ly dry before linking equipment or supplying electric power Troubleshooting DAP Audio ZoneControl MKII This troubleshooting guide is meant to help solve simple problems If a problem occurs carry out t...

Page 14: ...h 80 KHz Stereo Inputs Line Input unbalanced Bandwidth 10 Hz to 55 KHz 3 dB Distortion THD N 0 007 at 4dBu 1Khz Bandwidth 80 KHz Equalization Hi Shelving 12 KHz 12 dB Mid EQ 2 5 KHz 12 dB Low Shelving...

Page 15: ...2005 DapAudio...

Reviews: