background image

 

15 

Product Specifications 
 

MODE 

  

VISION 1600 

VISION 2400 

VISION 3500 

Stereo Mode 

 8Ω 

2x 620Wrms 

2x840Wrms 

2x1200Wrms 

                             

4Ω 

2x 1050Wrms 

2x1360Wrms 

2x1920Wrms 

                             

2Ω 

2x 1500Wrms 

2x1920Wrms 

2x2850Wrms 

Bridge Mode  

8Ω 

2100Wrms 

2720Wrms 

3840Wrms 

                            

4Ω 

3000Wrms 

3840Wrms 

5700Wrms 

Frequency response 

  

8Hz-50kHz(-1dB) 

15Hz-35kHz(-1dB) 

THD+N 

<0.03% 

<0.03% 

<0.03% 

Slew rate 

30V/μs 

40V/μs 

44V/μs 

Damping factor at 8Ω 

400 

430 

400 

S/N ratio 

>103dB (A-weighed) 

Input sensitivity 

0.775V, 1V, 1.4V 

Max Input Voltage 

+22dBu 

Input Imp. 

20kΩ Balanced 

  

10kΩ Unbalanced 

Subsonic Filter (selectable) 

30Hz, 18dB/Oct 

Lowpass Filter (Selectable) 

none 

150Hz, 18dB/Oct 

Protection 

Fixed  limiter 

Selectable limiter  

  

 

Short circuit 

  

 

Input overload 

  

 

Output overload 

  

 

DC voltage 

  

 

High temperature 

  

  

Soft start 

Output modes (selectable) 

Stereo/parallel/bridge 

Cooling 

  

Multi speed fan 

Airflow 

  

Back to front 

Input/ link connector 

 

XLR/XLR 

XLR/XLR 

XLR/XLR 

Output connector 

  

2x speakon 

2x speakon/2x bindingpost 

Groundlift switch 

  

yes 

yes 

yes 

Power supply 

AC 240V-50Hz  

Main fuse 

  

15AT 5x20 

15AT 6x32 

18AT 6x32 

Power consumption(full power 4

Ω

 3000W 

3430W  

4800W  

Gross weight 

24.62kg 

33.8kg 

36.06kg 

Dimensions (WxHxD) 

483x89x455mm 

483x132x455mm 

 

Design and product specifications are subject to change without prior notice. 

 
 

 

 

 

 

 

Website: 

www.Dap-audio.info 

Email: 

[email protected]

 

Summary of Contents for Vision 1600 ORDERCODE D4151

Page 1: ...Vision mkII Vision 1600 ORDERCODE D4151 Vision 2400 ORDERCODE D4152 Vision 3500 ORDERCODE D4153...

Page 2: ...DAP Audio for more excellent audio products We design and manufacture professional audio equipment for the entertainment industry New products are being launched regularly We work hard to keep you our...

Page 3: ...o Vision 1600 2400 3500 Product Guide Warning Safety instructions Operating Determinations Description Features Overview Front panel Overview Back panel Operation Connection Cables Maintenance Replaci...

Page 4: ...duce the system s life Do not open the device and do not modify the device Do not open this device Risk hazardous radiation exposure Only use system indoor avoid contact with water or other liquids Av...

Page 5: ...se the components are operated at their limits Avoid ground loops Always be sure to connect the power amps and the mixing console to the same electrical circuit to ensure the same phase If system is d...

Page 6: ...V 1V and 1 4V Bridge parallel or stereo mode 30 Hz Hi pass filter 3 dB 18 dB oct Ground selector Selectable crossover Low pass 150 Hz 18 dB oct Back to front airflow Amplifier has softstart and separa...

Page 7: ...seconds during this time the power amplifier makes an auto test When the LED dims it means the power amplifier is ready to work 3 SIGNAL Indicator The illumination of the LED indicates a safe operati...

Page 8: ...entiometer allows the adjustment of the channel 2 input level Right channel In bridge mode this potentiometer is disabled 10 Handles Handles are used for easy transportation Backpanel Fig 2 11 Channel...

Page 9: ...ition 22 Channel 2 Speakon Output Connect this Speakon output to a speaker Use connections 1 and 1 23 IEC Power Connector with integrated fuse holder Vision 1600 only 24 High Pass Filter Selector Visi...

Page 10: ...20V specification product on 240V power or vice versa Install this device on a flat surface not bending or curved Do not supply power before all components of the system are set up and connected prope...

Page 11: ...tion Output volume can be adjusted by means of the two potentiometers Connect the 2 speakers to the binding posts Parallel mode using Speakon outputs Fig 5 In this mode connect the input CH1 to your m...

Page 12: ...be adjusted by means of the two potentiometers Connect the 2 speakers to the binding posts Bridge mode using Speakon outputs Fig 7 In this mode connect the input CH1 to your mixer s outputs Put the s...

Page 13: ...Vision 2400 and 3600 only Fig 8 In this mode connect the input CH1 to your mixer s outputs Put the selector on the bridge position Output volume can be adjusted with channel 1 potentiometer Connect th...

Page 14: ...ife and reliability which is always to your advantage Periodically check that your cables are in good condition that they are correctly wired and that all their contacts are in good condition a great...

Page 15: ...13 Compensation of interference with balanced connections...

Page 16: ...er Turn the screwdriver to the left at the same time gently push a bit Turn and Push The fuse will come out 3 Remove the broken fuse If brown or unclear it is burned out 4 Insert the replacement fuse...

Page 17: ...0Hz 18dB Oct Lowpass Filter Selectable none 150Hz 18dB Oct Protection Fixed limiter Selectable limiter Short circuit Input overload Output overload DC voltage High temperature Soft start Output modes...

Page 18: ...2008 DapAudio...

Reviews: